Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Mechanical device malfunction remains a known issue in left ventricular assist devices (LVADs). We investigated the incidence of mechanical device malfunction in the HeartMate II and HeartMate 3 LVADs. We conducted a retrospective study of all HeartMate II and HeartMate 3 LVADs implanted in our center. We evaluated major malfunction, potential major malfunction, minor malfunction, and need of device exchange. In total, 163 patients received an LVAD; in 63 (39%) a HeartMate II, and in 100 (61%) a HeartMate 3, median support time of respectively 24.6 months (interquartile range [IQR]: 32.4) and 21.1 months [IQR: 27.2]. Mechanical device malfunction, consisting of both major and potential major malfunction, occurred significantly less in the HeartMate 3 patients with a hazard ratio (HR) of 0.37 (95% confidence interval [CI]: 0.15-0.87, p = 0.022). Major malfunction alone occurred significantly less in HeartMate 3 patients with a HR of 0.18 (95% CI: 0.05-0.66, p = 0.009). HeartMate 3 patients had a significantly decreased hazard of a pump or outflow graft exchange (HR 0.13, 95% CI: 0.08-0.81, p = 0.008). System controller defects occurred significantly less in HM 3 patients ( p = 0.007), but battery-clips defects occurred significantly more in HM 3 patients ( p = 0.039). Major device malfunction including pump or outflow graft exchange occurred significantly less in HeartMate 3 compared to HeartMate II, while minor malfunctions were similar. Periodical assessment of the technical integrity of the device remains necessary during long-term LVAD support.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/MAT.0000000000001877 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!