Feuerbacher, JF, Jacobs, MW, Dragutinovic, B, Goldmann, J-P, Cheng, S, and Schumann, M. Validity and test-retest reliability of the Vmaxpro sensor for evaluation of movement velocity in the deep squat. J Strength Cond Res 37(1): 35-40, 2023-We aimed at assessing the validity and test-retest reliability of the inertial measurement unit-based Vmaxpro sensor compared with a Vicon 3D motion capture system and the T-Force sensor during an incremental 1-repetition maximum (1RM) test and at submaximal loads. Nineteen subjects reported to the laboratory for the 1RM test sessions, whereas 15 subjects carried out another 3 sessions consisting of 3 repetitions with 4 different intensities (30, 50, 70, and 90% of 1RM) to determine the intra- and interday reliability. The Vmaxpro sensor showed high validity (Vicon: R2 = 0.935; T-Force: R2 = 0.968) but an overestimation of the mean velocities (MVs) of 0.06 ± 0.08 m·s-1 and 0.06 ± 0.06 m·s-1 compared with Vicon and T-Force, respectively. Regression analysis indicated a systematic bias that is increasing with higher MVs. The intraclass correlation coefficients (ICCs) for Vmaxpro were moderate to high for intraday (ICC: 0.662-0.938; p ≤ 0.05) and for interday (ICC: 0.568-0.837; p ≤ 0.05) reliability, respectively. The Vmaxpro is a valid and reliable measurement device that can be used to monitor movement velocities within a training session. However, practitioners should be cautious when assessing movement velocities on separate days because of the moderate interday reliability.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1519/JSC.0000000000004207 | DOI Listing |
Life (Basel)
December 2024
Department of Physical Education and Sport Performance, Vasile Alecsandri University, 600115 Bacau, Romania.
(1) Background: Regardless of the level of physical activity, performance monitoring is a valuable component of the training process. The aim of this research was to assess the reliability and sensitivity of parameter measurements using the Enode/Vmaxpro sensor. (2) Methods: Metric characteristics were examined for average velocity, peak velocity, average power, peak power, movement length, and movement duration.
View Article and Find Full Text PDFSensors (Basel)
November 2024
Department of Sport Sciences and Physical Education, Nord University, 7600 Levanger, Norway.
The aim of this study was to compare barbell velocities at different intensities and estimated 1-RM with actual 1-RM measured with different measuring tools in bench presses and squats. Fourteen resistance-trained athletes (eight men, six women, age 28.1 ± 7.
View Article and Find Full Text PDFFront Physiol
September 2024
Department for Sport and Exercise Science, German University of Health and Sport, Ismaning, Germany.
Introduction: While maximum strength diagnostics are applied in several sports and rehabilitative settings, dynamic strength capacity has been determined via the one-repetition maximum (1RM) testing for decades. Because the literature concerned several limitations, such as injury risk and limited practical applicability in large populations (e.g.
View Article and Find Full Text PDFBiol Sport
January 2024
Department of Molecular and Cellular Sports Medicine, Institute of Cardiovascular Research and Sports Medicine, German Sport University, Cologne, Germany.
We investigated the ecological validity of an inertial measurement unit (IMU) (Vmaxpro) to assess the movement velocity (MV) during a 1-repetition maximum (1RM) test and for the prediction of load-velocity () variables, as well as the ecological intra- day and inter-day reliability during free-weight bench press (BP) and squat (SQ). Furthermore, we provide recommendations for the practical use of the sensor. Twenty-three strength-trained men completed an incremental 1RM test, whereas seventeen men further participated in another 3 sessions consisting of 3 repetitions with 4 different loads (30, 50, 70 and 90% of 1RM) to assess validity and intra- and inter-day reliability, respectively.
View Article and Find Full Text PDFSci Rep
May 2023
Sport Performance Research Institute New Zealand (SPRINZ), Auckland University of Technology, Auckland, New Zealand.
This study examined the reproducibility of GymAware, PUSH2 and Vmaxpro velocity monitoring devices during resistance training (RT). The sensitivity of these devices to detect the smallest changes in velocity that correspond to true changes in RT performance was also investigated. Fifty-one resistance-trained men and women performed an incremental loading (1RM) test, and two repetitions to failure tests with different loads, 72 h apart.