A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

EVALUATION OF PATIENT-SPECIFIC IMRT QUALITY ASSURANCE AND POINT DOSE MEASUREMENT FOR COMPLEX HEAD AND NECK AND BRAIN CANCER USING GAFCHROMIC EBT3 FILM. | LitMetric

EVALUATION OF PATIENT-SPECIFIC IMRT QUALITY ASSURANCE AND POINT DOSE MEASUREMENT FOR COMPLEX HEAD AND NECK AND BRAIN CANCER USING GAFCHROMIC EBT3 FILM.

Radiat Prot Dosimetry

Centre for Cosmology, Astrophysics, and Space Science, GLA University, Mathura 281406, Uttar Pradesh, India.

Published: February 2023

Patient-specific intensity-modulated radiation therapy (IMRT) quality assurance (QA) is essential for complex radiotherapy treatment as it involves complex intensity modulation and high-dose gradient regions. IMRT QA was performed by point dose verification and two-dimensional (2D) dose distribution measurement using gamma method. Calibrated External Beam Therapy 3 (EBT3) film was used for point dose and pre-treatment verification of 10 IMRT plans, five complex Head and Neck (HN) and five brain cases. The gamma passing rate (GPR) was evaluated for 3%/3 mm gamma criteria and compared with 2D array. Isocentre dose was measured for all 10 IMRT plans on EBT3 film. Percentage deviation of point dose measurement from TPS calculated was found 0.4% for brain cases and 2.9% for HN cases. The GPR for 3%/3 mm criteria was obtained higher than 95% for brain and HN cases. Results suggest that film dosimetry is also a reliable verification system for patient-specific IMRT QA as the 2D array.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncac250DOI Listing

Publication Analysis

Top Keywords

point dose
16
ebt3 film
12
brain cases
12
patient-specific imrt
8
imrt quality
8
quality assurance
8
dose measurement
8
complex head
8
head neck
8
neck brain
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!