Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Home use of a buffer-containing extraction device for fecal calprotectin determination can bypass the labor-intensive extraction procedure and potentially prevent degradation at room temperature.
Methods: In this prospective cross-sectional observational study, 2 CALiaGold tubes (extraction device) and one native tube were filled from the same bowel movement by patients with inflammatory bowel disease. Afterwards patients completed a questionnaire including whether they preferred the extraction device or the normal sampling method. All tubes were sent to the laboratory and when they arrived, 2 more CALiaGold tubes were filled at the laboratory from the native sample. The fecal calprotectin concentrations in all tubes were measured by a particle-enhanced turbidimetric immunoassay.
Results: Fifty-three patients were included in the study. Fecal calprotectin levels were significantly higher in samples extracted by the patient compared to the analyst-performed extractions. When patients were divided into 3 groups (i.e., fecal calprotectin levels <50 ug/g, 50 to 200 µg/g, and >200 µg/g) a substantial concordance was found (Cohen kappa 0.654). Patients sampling imprecision was higher (P < 0.018, median CV 16%) compared to the analyst. Most patients preferred this extraction device.
Conclusions: Patient-performed fecal calprotectin extraction seems a realistic alternative sampling method and is preferred by most patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/jalm/jfac078 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!