A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Reliability of Patient-Performed Fecal Calprotectin Testing in Inflammatory Bowel Disease. | LitMetric

The Reliability of Patient-Performed Fecal Calprotectin Testing in Inflammatory Bowel Disease.

J Appl Lab Med

Department of Clinical Chemistry, Amsterdam University Medical Centers, Amsterdam Gastroenterology Endocrinology Metabolism Research Institute, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands.

Published: March 2023

Background: Home use of a buffer-containing extraction device for fecal calprotectin determination can bypass the labor-intensive extraction procedure and potentially prevent degradation at room temperature.

Methods: In this prospective cross-sectional observational study, 2 CALiaGold tubes (extraction device) and one native tube were filled from the same bowel movement by patients with inflammatory bowel disease. Afterwards patients completed a questionnaire including whether they preferred the extraction device or the normal sampling method. All tubes were sent to the laboratory and when they arrived, 2 more CALiaGold tubes were filled at the laboratory from the native sample. The fecal calprotectin concentrations in all tubes were measured by a particle-enhanced turbidimetric immunoassay.

Results: Fifty-three patients were included in the study. Fecal calprotectin levels were significantly higher in samples extracted by the patient compared to the analyst-performed extractions. When patients were divided into 3 groups (i.e., fecal calprotectin levels <50 ug/g, 50 to 200 µg/g, and >200 µg/g) a substantial concordance was found (Cohen kappa 0.654). Patients sampling imprecision was higher (P < 0.018, median CV 16%) compared to the analyst. Most patients preferred this extraction device.

Conclusions: Patient-performed fecal calprotectin extraction seems a realistic alternative sampling method and is preferred by most patients.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jalm/jfac078DOI Listing

Publication Analysis

Top Keywords

fecal calprotectin
24
extraction device
12
patient-performed fecal
8
inflammatory bowel
8
bowel disease
8
caliagold tubes
8
preferred extraction
8
sampling method
8
calprotectin levels
8
patients
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!