Aim: Abutment screw loosening of implant-supported prosthesis causes a mismatch between the abutment and the implant. This screw loosening is influenced by the implant-abutment connection type, however, with contradictory results reported in different studies. The present study evaluates the stability of abutment-implant connections in three different systems before and after the fatigue test.
Settings And Design: Thirty implants (4.3 mm in diameter and 12 mm in length) were divided into three groups of 10: Implantium, Zimmer, and straight internal hexagonal connection (SIC) implants.
Materials And Methods: Two torques of 35 Ncm with an interval of 10 min were applied, followed by measuring removal torque value (RTV). The samples were re-torqued and then underwent a simulation of 1-year chewing clinical performance of dental implant under axial force of 400 N, with a frequency of 8 Hz (one million cycles). After fatigue test, the RTV was calculated and recorded.
Statistical Analysis: The mean RTVs obtained before and after cyclic load were analyzed by SPSS version 22 software using multivariate analysis.
Results: Significant differences in RTV and role of cyclic loading were found between SIC and Implantium groups (P = 0.006 and 0.021, respectively), as well as between Zimmer and SIC groups (P = 0.032 and 0.006, respectively), but not between Zimmer and Implantium groups (P = 0.771 and 0.248, respectively).
Conclusion: The type of connection could affect the screw loosening, the preload loss, and the implant component stability. SIC group revealed the highest RTVs before and after cyclic loading.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9709864 | PMC |
http://dx.doi.org/10.4103/jips.jips_247_21 | DOI Listing |
Medicina (Kaunas)
January 2025
Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.
Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.
View Article and Find Full Text PDFZhongguo Gu Shang
January 2025
Department of Orthopaedics, Sir Run Run Shaw Hospital, Hangzhou 310016, Zhejiang, China.
Objective: To observe the clinical outcomes of anterior approach for the revision surgery following unsuccessful bone cement augmentation in osteoporotic vertebral compression fractures.
Methods: A total of 10 patients who experienced unsuccessful bone cement augmentation underwent anterior revision surgery between January 2020 and December 2021. There were 2 males and 8 females.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
January 2025
Department of Orthopedic Trauma, Beijing Jishuitan Hospital, Beijing, 100035, P. R. China.
Objective: To explore effectiveness of TiRobot-assisted screw implantation in the treatment of coracoid process fractures of the scapula.
Methods: A retrospective analysis was conducted on the clinical data from 24 patients with coracoid process fractures of the scapula admitted between September 2019 and January 2024 and met selection criteria. Among them, 12 patients underwent TiRobot-assisted screw implantation (robot group) and 12 underwent manual screw implantation (control group) during internal fixation.
Orthop Surg
January 2025
Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China.
Background: Iatrogenic cervical kyphosis (ICK) often requires complex anterior and posterior correction, which is associated with multiple complications. Consequently, there is a need to investigate alternative treatment approaches that streamline the operative process and markedly diminish postoperative complications. This study, therefore, aimed to evaluate the feasibility and efficacy of a single-stage anterior controllable antedisplacement fusion (ACAF) in revision surgeries for ICK.
View Article and Find Full Text PDFJ Orthop Sci
January 2025
Department of Spine Surgery, Anshun People's Hospital, Anshun, China. Electronic address:
Background: Degenerative lumbar diseases (DLDs) often have significant impacts on patients' quality of life, particularly when cage retropulsion (CR) occurs following lumbar interbody fusion (LIF). In this study, we conducted a meta-analysis to assess the risk factors associated with CR after LIF.
Methods: We retrieved literatures analyzing the risk factors associated with CR following LIF from seven databases.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!