Daily dose evaluation based on corrected CBCTs for breast cancer patients: accuracy of dose and complication risk assessment.

Radiat Oncol

Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands.

Published: December 2022

Objectives: The goal of this study is to validate different CBCT correction methods to select the superior method that can be used for dose evaluation in breast cancer patients with large anatomical changes treated with photon irradiation.

Materials And Method: Seventy-six breast cancer patients treated with a partial VMAT photon technique (70% conformal, 30% VMAT) were included in this study. All patients showed at least a 5 mm variation (swelling or shrinkage) of the breast on the CBCT compared to the planning-CT (pCT) and had a repeat-CT (rCT) for dose evaluation acquired within 3 days of this CBCT. The original CBCT was corrected using four methods: (1) HU-override correction (CBCT), (2) analytical correction and conversion (CBCT), (3) deep learning (DL) correction (CT) and (4) virtual correction (CT). Image quality evaluation consisted of calculating the mean absolute error (MAE) and mean error (ME) within the whole breast clinical target volume (CTV) and the field of view of the CBCT minus 2 cm (CBCT-ROI) with respect to the rCT. The dose was calculated on all image sets using the clinical treatment plan for dose and gamma passing rate analysis.

Results: The MAE of the CBCT-ROI was below 66 HU for all corrected CBCTs, except for the CBCT with a MAE of 142 HU. No significant dose differences were observed in the CTV regions in the CBCT, CT and CT. Only the CBCT deviated significantly (p < 0.01) resulting in 1.7% (± 1.1%) average dose deviation. Gamma passing rates were > 95% for 2%/2 mm for all corrected CBCTs.

Conclusion: The analytical correction and conversion, deep learning correction and virtual correction methods can be applied for an accurate CBCT correction that can be used for dose evaluation during the course of photon radiotherapy of breast cancer patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9746176PMC
http://dx.doi.org/10.1186/s13014-022-02174-4DOI Listing

Publication Analysis

Top Keywords

dose evaluation
16
breast cancer
16
cancer patients
16
cbct
11
correction
9
corrected cbcts
8
cbct correction
8
correction methods
8
rct dose
8
analytical correction
8

Similar Publications

Remission of asthma can occur as part of the natural history of the disease; however, the use of biologics can result in disease remission in some patients. In this post hoc analysis of the RELIght study, we aimed to evaluate clinical remission in real life among patients treated with mepolizumab, to detect possible differences between "remitters" and "nonremitters," and to evaluate possible predictors of remission. Clinical remission was defined as the absence of asthma exacerbations, discontinuation of oral corticosteroids (OCS), achievement of asthma control (Asthma Control Test [ACT] ≥ 20), and stable or improved lung function.

View Article and Find Full Text PDF

Background: The treatment of advanced colorectal cancer (CRC) has progressed slowly, with chemotherapy combined with targeted therapy being the first-line treatment for the disease, but the improvement in efficacy is not satisfactory. Compound Kushen injection (CKI) is one of the representative drugs of anti-cancer Chinese herbal injection drugs, which has been widely used in the adjunct treatment of cancer in China. The aim of this trial is to evaluate the efficacy and safety of CKI combined with first-line treatment of advanced CRC.

View Article and Find Full Text PDF

Background/aim: HyperArc (HA) is an automated planning technique enabling single-isocenter brain stereotactic radiotherapy (SRT); however, dosimetric outcomes may be influenced by the planner's expertise. This study aimed to assess the impact of institutional experience on the plan quality of HA-SRT for both single and multiple brain metastases.

Materials And Methods: Twenty patients who underwent HA-SRT for single metastasis between 2020 and 2021 comprised the earlier group, while those treated between 2022 and 2024 constituted the later group.

View Article and Find Full Text PDF

Background/aim: Autologous stem cell transplantation (ASCT) is the standard strategy after induction therapy for newly diagnosed transplant-eligible multiple myeloma. High-dose melphalan (HDM) conditioning has been the recommended treatment regimen for a long time. No other conditioning regimen has been proven safer and more effective.

View Article and Find Full Text PDF

Background/aim: This study aimed to predict the optimal timing for adaptive radiation therapy (ART) using two-dimensional X-ray image-based water equivalent thickness (2DWET).

Patients And Methods: Forty patients with oropharyngeal and hypopharyngeal cancer underwent Computed Tomography (CT) rescanning during treatment. An adaptive score (AS) was proposed to guide ART decisions based on changes in four dose indices: target coverage, spinal cord dose, parotid gland dose, and over-dose volume.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!