Pharmaceutical product development guided by Quality by Design (QbD) is based on a complete understanding of the critical process parameters (CPPs) that are important for achieving the desired product critical quality attributes (CQAs). The effect of process settings, such as the screw speed, the throughput, the barrel temperature, and the screw configuration, is a well-known factor in the setup of pharmaceutical hot melt extrusion (HME) processes. A CPP that has not yet been extensively researched is the type of cross-section geometry of the screw elements. Typically, pharmaceutical extruders have double-flighted screw cross-sections, with some elements having a single- or triple-flighted element section. The exception is a NANO16 extruder from Leistritz, with all screw elements having a triple-flighted screw geometry. We investigated the process setup and scale-up to a double-flighted extruder experimentally and in silico via a digital twin. Two formulations were processed on a NANO16 extruder and virtually transferred to a ZSE18 double-flighted co-rotating twin-screw extruder. Detailed smoothed particle hydrodynamics simulations of all screw elements available from both extruders were performed, and their efficiency in conveying, pressure build-up, and power consumption were studied. Reduced-order 1D HME simulations, which were carried out to investigate the process space and scalability of both extruders, were experimentally validated.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijpharm.2022.122469 | DOI Listing |
J Clin Med
December 2024
Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, 1-1-1, Tennodai, Tsukuba 305-8575, Ibaraki, Japan.
Proximal femoral fractures are particularly common in older adults, and cases requiring conversion to total hip arthroplasty may arise because of treatment failure or osteoarthritis. Fractures around the distal screw removal holes can be problematic. This study aimed to analyze the relationship between stem length and femoral stress distribution to determine the optimal stem length.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
School of Civil Engineering, Beijing Jiaotong University, Haidian District, Beijing 100044, China.
Existing support systems for thermal pipeline trenches often fail to meet the specific needs of narrow strips, tight timelines, and short construction periods in urban environments. This study introduces a novel recyclable, non-embedded support system composed of corrugated steel plates, retractable horizontal braces, angle steel, and high-strength bolts designed to address these challenges. The system's effectiveness was validated through prototype testing and optimized using Abaqus finite element simulations.
View Article and Find Full Text PDFJ Craniofac Surg
January 2025
Department of Craniomaxillofacial Surgery, Plastic Surgery Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China.
Objective: Finite element analysis (FEA) of the biomechanical properties of the modified extraoral distractor device used in the mandibular distraction of craniofacial microsomia patients.
Materials And Methods: Finite element analysis (FEA) models of 5 patients under 2 working conditions, the instance when the distractor is activated and when the distractor participates in mastication, were included in the current study. To conduct the FEA, load boundary conditions (35.
Sci Rep
January 2025
Biomedical Engineering Department, Faculty of Engineering, Helwan University, Cairo, Egypt.
Car accidents, infections caused by bacteria or viruses, metastatic lesions, tumors, and malignancies are the most frequent causes of chest wall damage, leading to the removal of the affected area. After excision, artificial bone or synthetic materials are used in chest wall reconstruction to restore the skeletal structure of the chest. Chest implants have traditionally been made from metallic materials like titanium alloys due to their biocompatibility and durability.
View Article and Find Full Text PDFInjury
December 2024
Golden Jubilee Medical Center, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Background: Severe metaphyseal comminution and sizable bone defect of the distal femur are high risks of fixation failure. To date, no exact magnitude of comminution and bone loss is determined as an indication for augmentation of fixation construct. The present study aimed to investigate the influence of metaphyseal gap width, working length, and screw distribution on the stability of the fixation construct.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!