Rapid Quantitation of Four Nitrosamine Impurities in Angiotensin Receptor Blocker Drug Substances.

J Pharm Sci

Division of Product Quality Research, Office of Testing and Research, Office of Pharmaceutical Quality, Center for Drug Evaluation and Research, Food and Drug Administration, 10903 New Hampshire Ave., Life Science Building-64, Silver Spring, MD 20993 USA. Electronic address:

Published: May 2023

AI Article Synopsis

Article Abstract

Starting in July 2018, the FDA alerted patients and health care professionals to the recall of ARBs such as valsartan by several pharmaceutical companies because of their potential contamination with carcinogenic nitrosamine impurities, including: (1) N-nitrosodimethylamine (NDMA), (2) N-nitrosodiethylamine (NDEA), (3) N-nitrosoethylisopropylamine (NEIPA), (4) N-nitrosodiisopropylamine (NDIPA), (5) N-nitrosodibutylamine (NDBA) and (6) N-nitroso-N-methyl-4-aminobutyric acid (NMBA). The FDA initiated a laboratory investigation to develop analytical procedures to test multiple lots of marketed ARB drugs to determine the possible presence of carcinogenic impurities and, if present, quantitate the levels of these impurities. Here the FDA laboratory developed and validated an automated micro-solid phase extraction MS/MS method, where all the analytes are not separated prior to elution to the MS, to simultaneously quantify NEIPA, NDIPA, NDBA and NMBA in ARB drug substances with an instrument sample analysis time of 12 seconds. The method was validated according to the ICH Q2(R1) guideline, and was determined to be specific, accurate, precise and linear over the corresponding nitrosamine analytical ranges. The method has been successfully implemented to quantitate the four nitrosamine impurities in 129 generic losartan, valsartan, olmesartan, irbesartan and telmisartan drug substance samples from 32 lots; and 32 losartan and valsartan drug product samples from 6 lots.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.xphs.2022.12.005DOI Listing

Publication Analysis

Top Keywords

nitrosamine impurities
12
drug substances
8
losartan valsartan
8
samples lots
8
impurities
5
rapid quantitation
4
nitrosamine
4
quantitation nitrosamine
4
impurities angiotensin
4
angiotensin receptor
4

Similar Publications

Based on the biologically active heterocycle quinoline, we successfully synthesized a series of quinoline-based dihydrazone derivatives (3a-3d). H NMR, C NMR, ESI-HRMS, IR, element analysis, UV/Vis spectroscopy and fluorescence spectroscopy were performed to comprehensively characterize their chemical structures, spectral properties and stability. Nitrosamine impurities were not detected in 3a-3d, and the systemic toxicological assessment indicated that the toxicity of 3a-3d was lower.

View Article and Find Full Text PDF

The presence of N-nitrosamine impurities in pharmaceutical products is well known. In 2019, it resulted in drug recall by the Food and Drug Administration (FDA). Soon, several groups identified the presence of many N-nitrosamines (NAs) in various Active Pharmaceutical Ingredients (APIs) and drug formulations worldwide.

View Article and Find Full Text PDF

The tumorigenic dose 50 (TD) is a widely used measure of carcinogenic potency which has historically been used to determine acceptable intake limits for carcinogenic compounds. Although broadly used, the TD model was not designed to account for important biological factors such as DNA repair and cell compensatory mechanisms, changes in absorption, etc., leading to the development of benchmark dose (BMD) approaches, which use more flexible dose-response models that are better able to account for these processes.

View Article and Find Full Text PDF

Visual, sensitive, and selective detection of carcinogenic substances is highly desired in portable health protection and practical medicine production. However, achieving this goal presents significant challenges with the traditional single-mode sensors reported so far, as they have limited sensing mechanisms and provide only a single output signal. Here, we report an effective optical and electrical dual-mode sensor for the visual, sensitive, and selective detection of -nitrosodiethylamine (NDEA), a typical volatile carcinogenic substance, leveraging the synergy of ionic liquid-doped liquid crystals (IL-LC).

View Article and Find Full Text PDF

N-nitrosamine impurities have been detected in a vast variety of drug substances and drug products, showing concern for regulatory aspects. To meet the regulatory requirement for the concerned impurity, a sensitive analytical method capable of quantifying these impurities at a lower level with accuracy and precision is required. This article focuses on the development and validation of an analytical method for the simultaneous detection of nine nitrosamine impurities in a single method for nebivolol drug product using liquid chromatography-mass spectrometry/mass spectrometry-atmospheric pressure chemical ionization (LC-MS/MS-APCI).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!