A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of mandibular repositioning surgery using new technology: Computer-aided design and manufacturing customized surgical cutting guides and fixation plates. | LitMetric

Introduction: Recent 3-dimensional technology advancements have resulted in new techniques to improve the accuracy of intraoperative transfer. This study aimed to validate the accuracy of computer-aided design and manufacturing (CAD-CAM) customized surgical cutting guides and fixation plates on mandibular repositioning surgery performed in isolation or combined with simultaneous maxillary repositioning surgery.

Methods: Sixty patients who underwent mandibular advancement surgery by the same surgeon were retrospectively evaluated by 3-dimensional surface-based superimposition. A 3-point coordinate system (x, y, z) was used to identify the linear and angular discrepancies between the planned movements and actual outcomes. Wilcoxon rank sum test was used to compare the outcomes between the mandible-only and the bimaxillary surgery groups with significance at P <0.05. Pearson correlation coefficient compared planned mandible advancement to the outcome from advancement planned. The centroid, which represents the mandible as a single unit, was computed from 3 landmarks, and the discrepancies were evaluated by the root mean square error (RMSE) for clinical significance set at 2 mm for linear discrepancies and 4° for angular discrepancies.

Results: There was no statistically significant difference between the planned and actual position of the mandible in either group when considering absolute values of the differences. When considering raw directional data, a statistically significant difference was identified in the y-axis suggesting a tendency for under-advancement of the mandible in the bimaxillary group. The largest translational RMSE for the centroid was 0.77 mm in the sagittal dimension for the bimaxillary surgery group. The largest rotational RMSE for the centroid was 1.25° in the transverse dimension for the bimaxillary surgery group. Our results show that the precision and clinical feasibility of CAD-CAM customized surgical cutting guides and fixation plates on mandibular repositioning surgery is well within clinically acceptable parameters.

Conclusion: Mandibular repositioning surgery can be performed predictably and accurately with the aid of CAD-CAM customized surgical cutting guides and fixation plates with or without maxillary surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajodo.2021.12.021DOI Listing

Publication Analysis

Top Keywords

mandibular repositioning
8
repositioning surgery
8
computer-aided design
8
design manufacturing
8
customized surgical
8
surgical cutting
8
cutting guides
8
guides fixation
8
fixation plates
8
accuracy mandibular
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!