A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Studying the dissolution of immediate release film coating using terahertz pulsed imaging. | LitMetric

Studying the dissolution of immediate release film coating using terahertz pulsed imaging.

Int J Pharm

Department of Chemical Engineering and Biotechnology, University of Cambridge, Philippa Fawcett Drive, CB3 0AS, Cambridge, UK. Electronic address:

Published: January 2023

Coated tablets introduce complexity to the dissolution process, even with readily soluble immediate release coating layers. Therefore, a more detailed understanding of the physical steps involved in the dissolution process can improve the efficiency of formulation and process design. The current study uses terahertz pulsed imaging to visualise the hydration process of microcrystalline cellulose (MCC) tablet cores that were film coated with an immediate release coating formulation upon exposure to the dissolution medium. Film coated tablets that were prepared from three levels of core porosity (10%, 20% and 30%) and with coating thickness in the range of 30μm to 250μm were investigated. It was possible to resolve and quantify the distinct stages of wetting of the coating layer, swelling of the MCC particles at the core surface, and dissolution of the coating layer followed by the ingress of dissolution media into the tablet core. The liquid transport process through the coating layer was highly consistent and scalable. The penetration rate through the coating layer and the tablet core both strongly depended on coating thickness and core porosity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijpharm.2022.122456DOI Listing

Publication Analysis

Top Keywords

coating layer
16
coating
9
terahertz pulsed
8
pulsed imaging
8
coated tablets
8
dissolution process
8
release coating
8
film coated
8
core porosity
8
coating thickness
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!