A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Indoor air particles in research vessel from Shanghai to Antarctic: Characteristics, influencing factors, and potential controlling pathway. | LitMetric

Indoor air particles in research vessel from Shanghai to Antarctic: Characteristics, influencing factors, and potential controlling pathway.

J Environ Sci (China)

Anhui Key Laboratory of Polar Environment and Global Change, Department of Environmental Science and Engineering, University of Science and Technology of China, Hefei 230026, China; Center for Excellence in Urban Atmospheric Environment, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China. Electronic address:

Published: April 2023

Despite millions of seafarers and passengers staying on ships each year, few studies have been conducted on the indoor air quality inside ship hulls. In this study, we investigated the levels and size distribution of indoor particulate matter during two cruises of the research vessel "Xuelong" from Shanghai to Antarctica. The results showed that the particle size less than 2.5 µm (PM), and particle size less than 10 µm (PM) concentrations in different rooms of the ship widely varied. We observed high particulate matter (PM) levels in some of the rooms. The mass concentration distribution was dominated by 1-4 µm particles, which may have been caused by the hygroscopic growth of fine particles. The dominant factors influencing PM concentrations were indoor temperature, relative humidity, and human activity. We quantified contributions of these factors to the levels of indoor particles using a generalized additive model. In clean rooms, the levels of indoor particles were controlled by temperature and relative humidity, whereas in polluted rooms, the levels of indoor particles were mainly influenced by temperature and human activity, which implied that controlling temperature and human activity would efficiently reduce the levels of indoor particles.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jes.2022.04.045DOI Listing

Publication Analysis

Top Keywords

levels indoor
16
indoor particles
16
human activity
12
indoor
8
indoor air
8
particulate matter
8
particle size
8
temperature relative
8
relative humidity
8
rooms levels
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!