A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Novel Vision Monitoring Method Based on Multi Light Points for Space-Time Analysis of Overhead Contact Line Displacements. | LitMetric

The article presents an innovative vision monitoring method of overhead contact line (OCL) displacement, which utilizes a set of LED light points installed along it. A light point is an, LED fed from a battery. Displacements of the LED points, recorded by a camera, are interpreted as a change of OCL shape in time and space. The vision system comprises a camera, properly situated with respect to the OCL, which is capable of capturing a dozen light points in its field of view. The monitoring system can be scaled by increasing the number of LED points and video cameras; thus, this method can be used for monitoring the motion of other large-size objects (e.g., several hundred meters). The applied method has made it possible to obtain the following novel results: vibration damping in a contact wire is nonlinear by nature and its intensity depends on the wire vibration amplitude; the natural frequency of contact wire vibration varies, and it is a function of vibration amplitude; the natural frequency of contact wire vibration also depends on the wire temperature. The proposed method can be used to monitor the uplift of contact and messenger wires in laboratory conditions, or for experimental OCL testing, as well as for verifying simulation models of OCL.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9739504PMC
http://dx.doi.org/10.3390/s22239281DOI Listing

Publication Analysis

Top Keywords

light points
12
contact wire
12
wire vibration
12
vision monitoring
8
monitoring method
8
overhead contact
8
led points
8
depends wire
8
vibration amplitude
8
amplitude natural
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!