This work reports the comparison of heat-treated and non-heat-treated laminated object-manufactured (LOM) 3D-printed specimens from mechanical and morphological viewpoints. The study suggests that heat treatment of the FDM-printed specimen may have a significant impact on the material characteristics of the polymer. The work has been performed at two stages for the characterization of (a) non-heat-treated samples and (b) heat-treated samples. The results for stage 1 (non-heat-treated samples) suggest that the infill density: 70%, infill pattern: honeycomb, and six number of discs in a single LOM-manufactured sample is the optimized condition with a compression strength of 42.47 MPa. The heat treatment analysis at stage 2 suggests that a high temperature: 65 °C, low time interval: 10 min, works equally well as the low temperature: 55 °C, high time interval: 30 min. The post-heat treatment near Tg (65 °C) for a time interval of 10 min improved the compressive strength by 105.42%.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9737080PMC
http://dx.doi.org/10.3390/polym14235098DOI Listing

Publication Analysis

Top Keywords

time interval
12
interval min
12
mechanical morphological
8
heat treatment
8
non-heat-treated samples
8
temperature °c
8
comparison heat
4
heat treated
4
non-heat-treated
4
treated non-heat-treated
4

Similar Publications

Background: Delta large-channel endoscopy and unilateral biportal endoscopy (UBE) are prominent minimally invasive techniques for treating lumbar spinal stenosis, known for minimal tissue damage, clear visualization, and quick recovery. However, rigorous controlled research comparing these procedures is scarce, necessitating further investigation into their respective complications and long-term effectiveness. This randomized controlled trial aims to compare their perioperative outcomes, focusing on postoperative recovery and complications over time.

View Article and Find Full Text PDF

Meta-analysis of MitraClip and PASCAL for transcatheter mitral edge-to-edge repair.

J Cardiothorac Surg

January 2025

Department of Internal Medicine II, Städtisches Klinikum Solingen, Solingen, Germany.

Background: Despite the promising results of both MitraClip and PASCAL systems for the treatment of mitral regurgitation (MR), there is limited data on the comparison of both systems regarding their safety and efficacy. We aim to compare both systems for MR.

Materials And Methods: Five databases were searched until October 2024.

View Article and Find Full Text PDF

Objective: This study aimed to investigate and compare the histological response of rabbit dental pulp after direct pulp capping with 3 different materials: mineral trioxide aggregate (MTA), nanoparticles of fluorapatite (Nano-FA), and nanoparticles of hydroxyapatite (Nano-HA) after 4 and 6-week time intervals.

Material And Methods: A total of 72 upper and lower incisor teeth from 18 rabbits were randomly categorized into 3 groups)24 incisors from six rabbits each. MTA Group: teeth were capped with MTA.

View Article and Find Full Text PDF

Purpose: This study is to evaluate duration of oocyte cryostorage and association with thaw survival, fertilization, blastulation, ploidy rates, and pregnancy outcomes in patients seeking fertility preservation.

Methods: Retrospective cohort study to evaluate clinical outcomes in patients who underwent fertility preservation from 2011 to 2023 via oocyte vitrification for non-oncologic indications. Primary outcome was thaw survival rate.

View Article and Find Full Text PDF

The increasing availability of coarse-scale climate simulations and the need for ready-to-use high-resolution variables drive the climate community to the challenge of reducing computational resources and time for downscaling purposes. To this end, statistical downscaling is gaining interest as a potential strategy for integrating high-resolution climate information obtained through dynamical downscaling over limited years, providing a clear understanding of the gains and losses in combining dynamical and statistical downscaling. In this regard, several questions can be raised: (i) what is the performance of statistical downscaling, assuming dynamical downscaling as a reference over a shared time window; (ii) how much the performance of statistical downscaling is affected by changes in the number of years available for training; (iii) how does the climate normal considered for the training affect the predictions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!