Nanotopography Evaluation of NiTi Alloy Exposed to Artificial Saliva and Different Mouthwashes.

Materials (Basel)

Faculty of Technical Sciences, University of Novi Sad, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia.

Published: December 2022

Nitinol (NiTi) alloy is a widely used material for the production of orthodontic archwires. Its corrosion behavior in conditions that exist in the oral cavity still remains a great characterization challenge. The motivation behind this work is to reveal the influence of commercially available mouthwashes on NiTi orthodontic archwires by performing non-electrochemical corrosion tests and quantifying the changes in the nanotopography of commercially available NiTi orthodontic wires. In this study, we examined the behavior of NiTi alloy archwires exposed for 21.5 days to different corrosive media: artificial saliva, Eludril, Aquafresh, and Listerine. The corrosion was characterized by contact mode atomic force microscopy (AFM) before and after the corrosion tests. A novel analysis methodology was developed to obtain insight into locations of material gain or material loss based on standard surface roughness parameters Sa, Sdr, Ssk, and S10z. The developed methodology revealed that fluoride-containing mouthwashes (Aquafresh and Listerine) dominantly cause material loss, while chloride-containing mouthwash (Eludril) can cause both material loss and material gain. The sample exposed to artificial saliva did not display significant changes in any parameter.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9739356PMC
http://dx.doi.org/10.3390/ma15238705DOI Listing

Publication Analysis

Top Keywords

niti alloy
12
artificial saliva
12
material loss
12
exposed artificial
8
orthodontic archwires
8
niti orthodontic
8
corrosion tests
8
aquafresh listerine
8
material gain
8
material
6

Similar Publications

: Orthodontic archwires undergo chemical and structural changes in the complex intraoral environment. The present work aims to investigate the safe duration for intraoral use (related to the nickel release hypothesis) of different types of nickel-containing wires. By analyzing how the nickel content (NC) varies over time, we aim to provide practical recommendations for the optimal use of said archwires.

View Article and Find Full Text PDF

Research progress on surface modification and coating technologies of biomedical NiTi alloys.

Colloids Surf B Biointerfaces

January 2025

College of New Energy and Materials, China University of Petroleum, Beijing 102249, China. Electronic address:

NiTi alloys are an important class of biomaterials with extensive clinical applications such as cardiovascular stents, orthodontic arch-wires, esophageal stents, orthopedic implants and more. However, the long-term implantation of NiTi alloys presents significant challenges due to their susceptibility to wear, corrosion and the excessive release of harmful nickel ions. These factors can severely compromise both the biocompatibility and the overall service life of the implants.

View Article and Find Full Text PDF

Objective: The present study aimed to evaluate the phase transformation behavior and elemental analysis of thermomechanical-treated nickel-titanium (NiTi) rotary instruments, TruNatomy (Dentsply Sirona), HyFlex CM (coltene, Whaledent), and Neoendo Flex (Orikam healthcare India), using differential scanning calorimetry (DSC), X-ray diffraction (XRD), and energy dispersive X-ray spectrometry.

Materials And Methods: A total of 18 NiTi rotary instruments, TruNatomy, Hyflex CM, Neoendo Flex, taper. 04, size 25 (except TruNatomy, size 26) were selected and were divided into three groups ( = 6).

View Article and Find Full Text PDF

Quality of Machined Surface and Cutting Force When Milling NiTi Alloys.

Materials (Basel)

December 2024

Faculty of Electrical and Computer Engineering, Cracow University of Technology, Warszawska 24, 31-155 Krakow, Poland.

The machining of shape memory alloys, such as NiTi, presents challenges due to their specific physical, chemical, and mechanical properties. This study investigated the effect of the helix angle of milling tools-both uncoated and coated-on the cutting forces and the surface roughness of the milling process for a NiTi alloy. Experiments were conducted using the tools with and without coatings at various helix angles (20°, 30°, and 40°) and under different machining conditions.

View Article and Find Full Text PDF

Background: The fracture of an endodontic instrument within the root canal system can occur during root canal therapy, complicating thorough cleaning and shaping. Consequently, managing the broken fragment becomes crucial.

Methods: Eighty Nickel-titanium (NiTi) #20 K-files (Mani, Tochigi, Japan) were cut 8 mm from the tip, fixed into a corkboard, and classified into five groups (n = 14 each).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!