A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of Isothermal Holding at 750 °C and 900 °C on Microstructure and Properties of Cast Duplex Stainless Steel Containing 24% Cr-5% Ni-2.5% Mo-2.5% Cu. | LitMetric

Changes in the microstructure and selected mechanical properties of two-phase ferritic-austenitic cast steel containing 24% Cr-5% Ni-2.5% Mo-2.5% Cu after isothermal holding at 750 °C and 900 °C are presented. The choice of the two temperatures of isothermal holding was dictated by the precipitation of brittle phases within a range of 600 °C-950 °C, while the holding time depended on the casting cooling time in the mould. Changes in the microstructure were studied by the SEM-EDS and XRD techniques. As a result of the decomposition of the eutectoid ferrite, a σ phase that was rich in Cr, Mo, and Ni and a secondary γ austenite with Widmannstätten morphology were formed. Compared to the austenite, the chemical composition of the secondary γ austenite showed depletion of Cr and Mo. In the ferrite, the presence of CrN nitrides was also detected. After a holding time of 3 h at 900 °C, these phases increased the hardness of the tested cast steel to approximately 275 HV. At the same time, the UTS value was recorded to decrease with the increasing temperature based on the tensile test results. At 750 °C, the value of UTS was 250 MPa for 1 h of holding and 345 MPa for 3 h of holding. These values decreased after increasing the temperature to 900 °C and amounted to 139 for 1 h holding and 127 MPa for 3 h holding. It was also found that the elongation values at 750 °C ranged from 7-10%, while they amounted to 35-37% at 900 °C. A fracture analysis of the tested cast steel showed that in the prevailing part, the fractures were made of ductile nature with an arrangement of dimples that is typical for this type of fracture. Non-metallic inclusions that are typical for cast steel (i.e., oxides and nitrides) were also found in the area of the fractures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9736604PMC
http://dx.doi.org/10.3390/ma15238569DOI Listing

Publication Analysis

Top Keywords

900 °c
20
750 °c
16
cast steel
16
isothermal holding
12
mpa holding
12
°c
10
holding 750
8
°c 900
8
steel 24%
8
24% cr-5%
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!