A detailed investigation of geogenic radon potential (GRP) was carried out near Graiguenamanagh town (County Kilkenny, Ireland) by performing a spatial regression analysis on radon-related variables to evaluate the exposure of people to natural radiation (i.e., radon, thoron and gamma radiation). The study area includes an offshoot of the Caledonian Leinster Granite, which is locally intruded into Ordovician metasediments. To model radon release potential at different points, an ordinary least squared (OLS) regression model was developed in which soil gas radon (SGR) concentrations were considered as the response value. Proxy variables such as radionuclide concentrations obtained from airborne radiometric surveys, soil gas permeability, distance from major faults and a digital terrain model were used as the input predictors. ArcGIS and QGIS software together with XLSTAT statistical software were used to visualise, analyse and validate the data and models. The proposed GRP models were validated through diagnostic tests. Empirical Bayesian kriging (EBK) was used to produce the map of the spatial distribution of predicted GRP values and to estimate the prediction uncertainty. The methodology described here can be extended for larger areas and the models could be utilised to estimate the GRPs of other areas where radon-related proxy values are available.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9737912PMC
http://dx.doi.org/10.3390/ijerph192315910DOI Listing

Publication Analysis

Top Keywords

geogenic radon
8
radon potential
8
soil gas
8
radon
5
detailed geogenic
4
potential mapping
4
mapping geospatial
4
geospatial analysis
4
analysis multiple
4
multiple geo-variables-a
4

Similar Publications

Radon (Rn) is a radioactive gas with well-documented harmful effects; the World Health Organization has confirmed it as a cancerogenic for humans. These detrimental effects have prompted Europe to establish national reference levels to protect the exposed population. This is reflected in European directive 59/2013/EURATOM, which has been transposed into the national regulations of EU Member States.

View Article and Find Full Text PDF

RADON in a high karst area of Montenegro - A case study.

Appl Radiat Isot

March 2025

School of Applied Mathematics and Informatics, University of Osijek, Trg Ljudevita Gaja 6, Osijek, Croatia.

The national radon surveys in Montenegro revealed that the highest annual average radon concentrations (C) in ground floors of dwellings and schools were found in a rural region characterized as a typical high-karst area. In this region, spanning approximately 800 km, C values in 9 houses and 16 schools ranged from 219 to 2494 Bq/m, with AM = 977 Bq/m. To investigate the causes of these elevated indoor radon concentrations, the following parameters were measured near the 25 surveyed buildings: soil humidity, electrical conductivity, pH, activity concentrations of Ra, U, U, Th and K, radon concentration in soil gas (c), soil permeability for radon gas (k), and gamma dose rate in the air.

View Article and Find Full Text PDF

This study assessed the geogenic radon potential using PECAME, an innovative tool designed to simultaneously measure soil-gas permeability and CO concentration - two key parameters for understanding radon transport in soil. Comparative field studies using the RADON-JOK device in various geological settings in Japan and Poland demonstrate the effectiveness of PECAME. These studies reveal a strong correlation between PECAME and RADON-JOK, with an R value of 0.

View Article and Find Full Text PDF

Apportioning radon contamination sources in underground spaces using a grey-box model.

J Hazard Mater

February 2025

Department of Earth and Environmental Sciences, Korea University, 145, Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea. Electronic address:

Article Synopsis
  • The study addresses the need for effective radon management indoors due to its carcinogenic risks, identifying both gaseous and aqueous radon as main sources.
  • Researchers developed a grey-box model that combines physical theories with data to better understand and apportion indoor radon sources.
  • Results show that indoor radon levels were significantly higher than EPA recommended limits, with aqueous radon degassing identified as the primary source, suggesting that the grey-box model could enhance mitigation strategies.
View Article and Find Full Text PDF

The urbanized area of Rome is largely built over volcanic deposits, characterized by a significant radionuclides content and consequently a high radon emanation potential. An accurate monitoring of workplaces and residential dwellings constitutes a first step towards mitigating the indoor radon exposure. Since radon diffusion dynamics involves complex interactions among many environmental parameters on different time scales, a proper assessment of radon concentration variations can be better achieved by means of active monitoring approaches.