Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Lab-based testing systems utilizing photoelectrochemical (PEC) biosensing methodologies for the ultrasensitive carcinoembryonic antigen (CEA) have been developed, although the majority have shown complicated operating procedures and dependence on precise apparatus. Herein, a portable photoelectrochemical split diagnostic platform based on a hollow CdS/CdMoO (h-CdS@CdMoO) shell-shell structured photoanode system was developed for ultrasensitive detection of CEA. Using a small LED flashlight as the excitation light source and a digital multimeter (DMM) as the signal readout device, real-time CEA on a paper-based printed screen electrode developed in-house was quickly detected. The composite h-CdS@CdMoO featured a special hollow shell-shell heterojunction structure that optimizes photon usage in the bulk phase on the one hand, and facilitates directed separation of the electrons and holes therein on the other. A split-sandwich immunoassay and detection antibodies for modified glucose oxidase were introduced into the paper-based photoanode test system, and the signals were displayed with a DMM to realize a point-of-care test for CEA. Under optimized conditions, the constructed portable PEC sensing system was sensitive to the target CEA from 0.02 to 50.0 ng mL with a detection limit of 11.3 pg mL. Interferent experiments and stability test evaluations demonstrate the specificity and robustness of the constructed paper-based portable PEC sensor. The portable, paper-based PEC immunoassay system developed offers a fresh way of exploring affordable, approachable sensors to satisfy both the relevant community medical testing demands and hospital objectives for quick testing.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.talanta.2022.124176 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!