Short-term clinic observation of misalignment and rotational stability after implantable collamer lens implantation.

Graefes Arch Clin Exp Ophthalmol

Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Nankai University Affiliated Eye Hospital, Clinical College of Ophthalmology Tianjin Medical University, Tianjin Eye Institute, Tianjin, 300020, China.

Published: May 2023

Purpose: We aimed to investigate misalignment (tilt and decentration) and rotational stability of the implantable collamer lens V4c 6 months after implantation and to explore the potential risk factors associated with postoperative misalignment and rotation.

Methods: A total of 36 eyes of 36 patients with high myopia and myopic astigmatism who underwent implantable collamer lens V4c implantation were included in this study. Tilt, decentration, and rotation of the implantable collamer lens were assessed postoperatively at l week, 1 month, 3 months, and 6 months. Correlation analysis was used to identify the potential risk factors for implantable collamer lens tilt, decentration, and rotation at 6 months postoperatively. Higher-order aberration was measured to evaluate the effect of implantable collamer lens misalignment on visual quality at pupil diameters of 4.0 mm and 6.0 mm.

Results: The tilt and decentration at the last follow-up were 2.43 ± 1.35° and 0.278 ± 0.160 mm, respectively. There was a significant positive correlation between tilt and decentration (r = 0.31, P = 0.046). No significant correlation was detected between implantable collamer lens decentration and internal higher-order aberrations (P > 0.05). The degree of implantable collamer lens rotation (3.11 ± 2.00°) was significantly associated with the vault (r =  - 0.422, P = 0.01), while it was positively associated with the preoperative anterior chamber depth (r = 0.36, P = 0.034). No significant correlation was found between postoperative astigmatism and rotation (r =  - 0.07, P = 0.351).

Conclusions: The implantable collamer lens V4c provides relatively stable misalignment and rotation after implantation. The ICL lens vault is a potential risk factor for postoperative implantable collamer lens rotation. The absolute value of decentration and tilt was relatively small, which showed no correlation with internal higher-order aberration in short-term observation.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00417-022-05929-7DOI Listing

Publication Analysis

Top Keywords

implantable collamer
40
collamer lens
40
tilt decentration
20
lens v4c
12
potential risk
12
lens
11
implantable
10
collamer
10
rotational stability
8
stability implantable
8

Similar Publications

Purpose: To evaluate the long-term effects of implantable collamer lens (ICL) V4c on the biomechanical and morphological properties of crystalline lenses in Chinese adults with high myopia using Brillouin microscopy (BM).

Methods: In this case-control study, 102 highly myopic eyes from 102 patients (18-48 years, preoperative spherical equivalent (SE): -6.00--21.

View Article and Find Full Text PDF

Introduction: This study evaluated the clinical outcomes of simultaneous implantable collamer lens (ICL) removal and phacoemulsification with intraocular lens (IOL) implantation in a multicenter study.

Methods: We retrospectively investigated 83 eyes of 72 patients requiring ICL extraction and cataract surgery at five institutions. Preoperatively and 3 months postoperatively, we determined visual acuity (logMAR), spherical equivalent refraction, and endothelial cell density (ECD), in addition to the preoperative backgrounds and the postoperative complications.

View Article and Find Full Text PDF

Purpose: In this study, we aimed to investigate the relationship between the intraocular levels of inflammatory factors and myopia-related retinal vascular and neuronal degeneration.

Patients And Methods: One hundred and forty-seven patients with Implantable Collamer Lens (ICL) implantation were enrolled and all participants received comprehensive ophthalmic examination. About 100~150 ul of aqueous humor was collected immediately before ICL surgery.

View Article and Find Full Text PDF

Background: Implantable collamer lens (ICL) could be an effective and safe treatment option for patient with keratoconus. The presence of cataract is considered a relative contraindication to the use of ICL. In this case report, we describe the outcomes of ICL implantation in an eye with keratoconus and splinter cortical cataract sparing the visual axis.

View Article and Find Full Text PDF

Purpose: To investigate the pharmacological accommodative changes of the anterior segment and its impact on the circumferential anterior chamber angle (ACA) after implantable collamer lens (ICL) implantation using swept-source optical coherence tomography (SS-OCT).

Setting: Eye and ENT Hospital, Fudan University, Shanghai, CHINA.

Design: Prospective randomized contralateral eye study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!