Purpose: To develop a custom coil and evaluate its utility for accelerated upper and infraglottic airway MRI at 3 T.
Methods: A 16-channel flexible and anatomy-conforming coil was developed to provide localized sensitivity over upper and infraglottic airway regions of interest. Parallel-imaging capabilities were compared against existing head and head-neck coils. SENSE geometry factor losses were quantified for retrospectively accelerating 3D MRI. Blinded image-quality ratings from two experts were performed. Spiral GRAPPA reconstructions were evaluated for a speaking task at a time resolution of 40 ms. Contrast-to-noise ratios between air and tissue at key landmarks along the vocal tract were compared. SENSE imaging with the custom coil in the lateral recumbent posture was evaluated. Multislice imaging was performed to image swallowing at 17 ms/frame via constrained reconstruction.
Results: The custom coil showed improved SENSE imaging up to 3-fold acceleration when accelerated along either the anterior-posterior or the superior-inferior direction and a net 4-fold acceleration when accelerated along both directions. Spiral GRAPPA reconstructions with the custom coil showed higher contrast-to-noise ratio when compared with existing coils. In the lateral posture, robust SENSE imaging was achieved at up to 2-fold and 3-fold acceleration levels in the superior-inferior and anterior-posterior directions, respectively. Key events of swallowing in the multislice dynamic images were identified by an otolaryngologist.
Conclusion: The coil provided improved parallel imaging of upper and infraglottic airway in both supine and lateral recumbent postures. It enabled efficient accelerated dynamic imaging of speaking and swallowing.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/mrm.29559 | DOI Listing |
IEEE J Solid-State Circuits
November 2024
Department of Electrical and Computer Engineering, Rice University, Houston TX, 77005, USA.
Miniature bioelectronic implants promise revolutionary therapies for cardiovascular and neurological disorders. Wireless power transfer (WPT) is a significant method for miniaturization, eliminating the need for bulky batteries in today's devices. Despite successful demonstrations of millimetric battery-free implants in animal models, the robustness and efficiency of WPT are known to degrade significantly under misalignment incurred by body movements, respiration, heart beating, and limited control of implant orientation during surgery.
View Article and Find Full Text PDFBiomed Res Int
January 2025
Center for Personalized Nanomedicine, Australian Institute for Bioengineering & Nanotechnology (AIBN), The University of Queensland, Brisbane, Queensland, Australia.
Environmental pollution has been a significant concern for the last few years. The leather industry significantly contributes to the economy but is one of Bangladesh's most prominent polluting industries. It is also responsible for several severe diseases such as cancer, lung diseases, and heart diseases of leather workers because they use bleaching agents and chemicals, and these have numerous adverse effects on human health.
View Article and Find Full Text PDFMed Phys
January 2025
Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.
Background: Radiofrequency (RF) transmit arrays play a crucial role in various MRI applications, offering enhanced field control and improved imaging capabilities. Designing and optimizing these arrays, particularly in high-field MRI settings, poses challenges related to coupling, resonance, and construction imperfections. Numerical electromagnetic simulation methods effectively aid in the initial design, but discrepancies between simulated and fabricated arrays often necessitate fine-tuning.
View Article and Find Full Text PDFNeuroimage
January 2025
Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, USA. Electronic address:
Introduction: Ultra-high-field magnetic resonance (MR) systems (7 T and 9.4 T) offer the ability to probe human brain metabolism with enhanced precision. Here, we present the preliminary findings from 3D MR spectroscopic imaging (MRSI) of the human brain conducted with the world's first 10.
View Article and Find Full Text PDFBiomedicines
December 2024
Department of Ophthalmology, School of Medicine, Sapporo Medical University, S1 W16 Chuo-ku, Sapporo City 060-8543, Hokkaido, Japan.
Background/objectives: The objective of the present study was to examine the unidentified effects that RHO-associated coiled-coil-containing protein kinase 1 and 2 antagonists exert on the transforming growth factor beta2-induced epithelial-mesenchymal transition of the human corneal stroma.
Methods: In the presence or absence of pan-RHO-associated coiled-coil-containing protein kinase inhibitors, ripasudil or Y27632 and RHO-associated coiled-coil-containing protein kinase 2 inhibitor, KD025, we analyzed the following: (1) planar proliferation caused by trans-endothelial electrical resistance and the cellular metabolic characteristics of the two-dimensional cultures of human corneal stroma fibroblasts; (2) the physical properties of a three-dimensional human corneal stroma fibroblasts spheroid; and (3) the gene expressions and their regulators in the extracellular matrix, along with the tissue inhibitors of metalloproteinases and matrix metalloproteinases and the endoplasmic reticulum stress-related factors of the two-dimensional and three-dimensional cultures in human corneal stroma fibroblasts.
Results: Exposure to 5 nM of the transforming growth factor beta2 markedly increased the trans-endothelial electrical resistance values as well as the metabolic function in two-dimensional cultures of human corneal stroma fibroblasts.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!