Robust Animal-Based Measures (ABMs) are fundamental in order to assess animal welfare, however in semi-extensive sheep farming systems is not easy to collect ABMs without inducing additional stress in the animals. Heart rate variability (HRV) is a non-invasive technique of assessing stress levels related to animal welfare. It is considered a sensitive indicator of the functional regulatory characteristics of the autonomic nervous system. Several studies investigated the use of HRV for welfare assessment in dairy cows while research on sheep is scarce. Moreover, assessing HRV in small ruminants at pasture is critical because of the lack of a solution adoptable for field conditions. This study aimed to evaluate if a smart textiles technology is comparable to a Standard base-apex electrocardiogram (ECG) for measuring HRV in small ruminants. Eight healthy Massese dairy sheep were recruited. Standard base-apex ECG and smart textiles technology (Smartex ECG) were simultaneously acquired for 5 min in the standing, unsedated, unclipped sheep. The ECG tracings were recorded when animals were standing quietly. The Bland-Altman test and the linear regression analysis were applied after parameter extraction in time, frequency, and non-linear methods to compare Smartex against standard base-apex ECG systems. The Bland-Altman test was applied to all HRV extracted parameters (Mean RR, pNN50, RMSSD, LF/HF, SampEn, SD1, SD2, stdRR) to evaluate the agreement between the two different instruments, and a linear regression analysis was performed to evaluate the relationship between the two methods. The smart textiles biotechnology was simple to wear and clean. It can be worn without using glue and without shaving the sheep's wool, limiting animal handling and stress. Bland Altman test reported a robust agreement between the two systems. In fact, the regression analysis of HRV parameters showed that half of the parameters recorded had an R2 coefficient >0.75. Results also showed a very small reproducibility coefficient that indicated that the two methods were really close to each other. Smartex textiles technology can be used for HRV evaluation in sheep species as a potential ABM for animal welfare assessment.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9722759 | PMC |
http://dx.doi.org/10.3389/fvets.2022.1018213 | DOI Listing |
Adv Healthc Mater
January 2025
School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario, L8S 4L8, Canada.
The predominant adverse health effects in care delivery result from hospital-acquired (nosocomial) infections, which impose a substantial financial burden on global healthcare systems. Integrating contact-killing antibacterial action, gas permeability, and antioxidant properties into textile coatings offers a transformative solution, significantly enhancing both medical and everyday protective applications. This study presents an innovative, pollution-free physical compounding method for creating a fluorescent biopolymer composite embedded with silicene-based heteroatom-doped carbon quantum dots for the production of functional textiles.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
Petrochemical Engineering Department, Faculty of Engineering, Pharos University, Alexandria, Egypt. Electronic address:
Textile materials are extensively used due to their advantageous properties; however, their inherent flammability presents significant safety risks, particularly in residential and historical settings. To mitigate these risks, the integration of flame-retardant agents into textile fabrics is essential for enhancing fire resistance and advancing sustainable development. In this study, cotton-polyester fabrics were treated with a flame-retardant composite containing nano graphene oxide (NGO), sodium hypophosphite dihydrate (SHFDH), and lignin (L).
View Article and Find Full Text PDFNat Commun
January 2025
Nanotechnology Center, School of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong, 999077, China.
Wireless energy-responsive systems provide a foundational platform for powering and operating intelligent devices. However, current electronic systems relying on complex components limit their effective deployment in ambient environment and seamless integration of energy harvesting, storage, sensing, and communication. Here, we disclose a coupling effect of electromagnetic wave absorption and moist-enabled generation on carrier transportation and energy interaction regulated by ionic diode effect.
View Article and Find Full Text PDFTalanta
January 2025
State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Engineering Research Center of Technical Textiles, Ministry of Education, College of Materials Science and Engineering, College of Science in Donghua University, State Key Laboratory of Polyolefins and Catalysis, Shanghai Key Laboratory of Catalysis Technology for Polyolefins (Shanghai Research Institute of Chemical Industry Co., Ltd., Shanghai), Key Laboratory of High Performance Fibers & Products, PR China. Electronic address:
Here, a green poly(ionic liquid)-regulated one-pot method is developed for the synthesis of Au@Pt core-shell nanospheres (PNSs) under mild reaction conditions in water. It is found that the poly(ionic liquid) poly[1-methyl-3-butyl (3-hydroxy) imidazole] chloride (PIL-Cl) is very vital to guide the construction of Au@Pt PNSs. The as-obtained Au@Pt-1 PNSs have perfect spherical outlines, porous core-shell structures and large specific surface area by which they exhibit excellent peroxidase-like activity in acidic media and can be used to develop a simple and reliable colorimetric sensing platform.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
School of Energy and Environment, City University of Hong Kong, Kowloon 999077, Hong Kong.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!