Aim: The purpose was to provide a practical and effective method for performing reliable Y dosimetry based on Tc-MAA and SPEC/CT. The impact of scatter correction (SC) and attenuation correction (AC) on the injected Y activity, lung shunt fraction (LSF) and the delivered dose to lung and liver compartments was investigated within the scope of the study.
Material And Methods: Eighteen eligible patients (F: 3, M: 15) were subjected to Y therapy. Tc-MAA (111-222 MBq) was injected into the targeted liver, followed by whole-body scan (WBS) with peak-window at 140 keV (15% width) and one down-scatter window. SPECT/CT scan was subsequently acquired encompassing lung and liver regions. The LSFs were fashioned from standard WBS LSFwb (St), scatter corrected WBS LSFwb (Sc), only scatter corrected SPECT LSFspect (NoAC-SC) and SPECT/CT with attenuation and scatter correction LSFspect (AC-SC). The absorbed doses that would be delivered to tumor and injected healthy liver were estimated using different calculation modes involving AC-SC (SPECT/CT), NoAC-SC (SPECT), NoAC-NoSC+LSFwb (SC), AC-SC + LSFwb (St), and NoAC-NoSC+LSFwb (St).
Results: The average deviations (range) in LSF values between standard LSFwb (St) and those from SPECT/CT (AC-SC), SPECT (NoAC-SC), and LSFwb (SC) were - 50% (- 29/- 71), - 32% (- 8/- 67), and - 45% (- 13/80), respectively. The suggested Y activity (GBq/Gy) was decreased within a range of 2-11%, 1-9%, and 2-7% by using LSFspect (AC-SC), LSFspect (NoAC-SC), and LSFwb (SC), respectively. Overall, two-sample t-test yielded no statistically significant difference (p < 0.05) in the absorbed doses to tumor and injected healthy liver between AC-SC (SPECT) and the rest of approaches with/and without AC and SC. However, a statistically significant difference (p < 0.05) was demonstrated in the lung shunt fractions and lung doses due to AC and SC. The LSFs from scatter corrected planar images LSFwb (SC) exhibited well agreement (R = 0.92) with SPECT/CT (AC-SC) and there was no statistically significant difference (P > 0.05) between both methods.
Conclusion: It was deduced that SPECT/CT with attenuation and scatter correction plays a crucial role in the measurements of lung shunt fraction and dose as well as the total number of Y treatments. However, the absorbed dose to tumors and injected healthy liver was minimally affected by AC and SC. Besides, a good agreement was observed between LSF datasets from SPECT/CT versus scatter corrected WBS that can be alternatively and effectively used in Y dosimetry.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9733257 | PMC |
http://dx.doi.org/10.1186/s12885-022-10392-y | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!