Purpose: We aimed to compare simple two-dimensional (2D) measurement with comprehensive three-dimensional (3D) volume rendering to determine loss of domain (LOD), a clinically important decision-making feature for incisional hernia repair.
Methods: In this single-center retrospective study, we analyzed the CT scans of a consecutive cohort of adult patients with a midline incisional hernia. The hernia sac- and abdominal cavity volumes were obtained by two different methods. The 2D method estimated the volumes using the corresponding height, width, and depth. The 3D method comprised of a volume rendering tool. For both methods, LOD was calculated according to the Sabbagh ratio (hernia sac volume / (hernia sac volume + abdominal cavity volume)). Taking the 3D method as the reference standard, the performance of the 2D method was expressed as positive predictive value (PPV) and negative predictive value (NPV) for LOD of more than- and less than 20%. The agreement between both methods was expressed as Cohen's kappa coefficient (kappa).
Results: We analyzed 92 CT scans. Agreement between both methods was high (kappa = 0.854, p = 0.0001); all 67 measurements for which the 2D method assessed LOD to be less than 20% were correctly classified (NPV = 100%), and 20 of 25 measurements for which the 2D method assessed LOD to be more than 20% were correctly classified (PPV = 80%).
Conclusions: The 2D method can exclude patients from perioperative actions needed for a more complex hernia. Since this method is easy to use and less time-consuming, it seems useful for the routine radiological assessment of LOD in clinical practice.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10029-022-02729-0 | DOI Listing |
ACS Nano
January 2025
National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230026, China.
Metal ions are indispensable to life, as they can serve as essential enzyme cofactors to drive fundamental biochemical reactions, yet paradoxically, excess is highly toxic. Higher-order cells have evolved functionally distinct organelles that separate and coordinate sophisticated biochemical processes to maintain cellular homeostasis upon metal ion stimuli. Here, we uncover the remodeling of subcellular architecture and organellar interactome in yeast initiated by several metal ion stimulations, relying on near-native three-dimensional imaging, cryo-soft X-ray tomography.
View Article and Find Full Text PDFSurg Radiol Anat
January 2025
Department of Neurosurgery, Saitama Sekishinkai Hospital, 2-37-20 Irumagawa, Sayama, Saitama, 350-1305, Japan.
Purpose: To describe a case of short common trunk of the occipital artery (OA) and ascending pharyngeal artery (APA) arising from the internal carotid artery (ICA).
Methods: A 36-year-old woman with a history of surgical resection of a right lateral ventricular meningioma and atheromatous plaque of the right ICA underwent cranial magnetic resonance (MR) imaging and MR angiography of the head and neck region with a 3-Tesla scanner.
Results: MR angiography of the neck region showed a small atheromatous plaque at the origin of the right ICA and an anomalous artery arising from the posteromedial aspect of the right ICA at the distal end of the carotid bulb.
Front Rehabil Sci
January 2025
Department of Orthopaedic Surgery Changi General Hospital, Singapore, Singapore.
Background: The prevalence of knee osteoarthritis in Southeast Asia has increased steadily over the years. When conservative management options fail, total knee arthroplasty (TKA) is a reliable surgical option. Despite over 90% post-operative satisfaction, the high volume of TKAs performed means that even a small percentage of dissatisfied patients holds significance.
View Article and Find Full Text PDFVet Med (Praha)
December 2024
Department of Veterinary Surgery, College of Veterinary Medicine, Jeonbuk National University, Jeollabuk-do, Republic of Korea.
Tibial torsion assessment is crucial for understanding deformities and malalignments that can lead to joint pathologies in dogs. Different methods such as radiography, computed tomography (CT), and three-dimensional (3D) volume-rendering techniques have been employed to measure tibial torsion. This study compared the accuracy and reliability of tibial torsion angle (TTa) measurements obtained using radiography and ultrasound tilting techniques against those obtained using the 3D volume-rendering method in small-to-medium-sized non-chondrodystrophic dogs.
View Article and Find Full Text PDFBioelectrochemistry
January 2025
Department of Bioengineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-Ku, Tokyo 113-8656, Japan. Electronic address:
Conductive nanofibers can exhibit excellent mechanical properties such as flexibility, elasticity, porosity, large surface area-to-volume ratio, etc making them suitable for a wide range of applications including biosensor development. Their large surface area provides more active sites for immobilization of large amount of bioreceptors enabling more interaction sites with the target analytes, enhancing sensitivity and detection capabilities. However, engineering conductive nanofibers with such excellent properties is challenging limiting their effective deployment for intended applications.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!