Intra-aortic and Intra-caval Balloon Pump Devices in Experimental Non-traumatic Cardiac Arrest and Cardiopulmonary Resuscitation.

J Cardiovasc Transl Res

Department of Anesthesiology and Intensive Care, Faculty of Medicine and Health, Örebro University, SE-701 85, Örebro, Sweden.

Published: August 2023

Intra-aortic balloon pump (IABP) use during CPR has been scarcely studied. Intra-caval balloon pump (ICBP) may decrease backward venous flow during CPR. Mechanical chest compressions (MCC) were initiated after 10 min of cardiac arrest in anesthetized pigs. After 5 min of MCC, IABP (n = 6) or ICBP (n = 6) was initiated. The MCC device and the IABP/ICBP had slightly different frequencies, inducing a progressive peak pressure phase shift. IABP inflation 0.15 s before MCC significantly increased mean arterial pressure (MAP) and carotid blood flow (CBF) compared to inflation 0.10 s after MCC and to MCC only. Coronary perfusion pressure significantly increased with IABP inflation 0.25 s before MCC compared to inflation at MCC. ICBP inflation before MCC significantly increased MAP and CBF compared to inflation after MCC but not compared to MCC only. This shows the potential of IABP in CPR when optimally synchronized with MCC. The effect of timing of intra-aortic balloon pump (IABP) inflation during mechanical chest compressions (MCC) on hemodynamics. Data from12 anesthetized pigs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10480270PMC
http://dx.doi.org/10.1007/s12265-022-10343-9DOI Listing

Publication Analysis

Top Keywords

balloon pump
16
mcc
13
iabp inflation
12
compared inflation
12
inflation mcc
12
intra-caval balloon
8
cardiac arrest
8
intra-aortic balloon
8
pump iabp
8
iabp cpr
8

Similar Publications

Cardiogenic shock (CS) in acute myocardial infarction (AMI) is a life-threatening syndrome characterized by systemic hypoperfusion that can quickly progress to multiorgan failure and death. Various devices and configurations of mechanical circulatory support (MCS) exist to support patients, each with unique pathophysiological characteristics. The Intra-aortic balloon pump can improve coronary perfusion, decrease afterload, and indirectly augment cardiac output.

View Article and Find Full Text PDF
Article Synopsis
  • Patients awaiting heart transplants often require colonoscopies due to bleeding or screening needs, but there's limited research on the safety of these procedures for individuals on inotropic medications or mechanical circulatory support.
  • A study was conducted from 2015 to 2021 with 92 heart failure patients undergoing colonoscopy while on advanced heart failure therapies, such as inotropes or mechanical devices.
  • Results indicated that the most common reason for colonoscopy was cancer screening, with significant findings including 8% of screening procedures revealing advanced adenomas and 17% of bleeding-related colonoscopies identifying sources needing intervention, but no major complications related to anesthesia were reported.
View Article and Find Full Text PDF

Background: Coronary artery bypass grafting (CABG) surgery has been a widely accepted method for treating coronary artery disease. However, its postoperative complications can have a significant effect on long-term patient outcomes. A retrospective study was conducted to identify before and after surgery that contribute to postoperative stroke in patients undergoing CABG, and to develop predictive models and recommendations for single-factor thresholds.

View Article and Find Full Text PDF

BACKGROUND Human metapneumovirus (hMPV), classified in the Pneumoviridae family, is primarily known for causing lower respiratory tract infections in children, the elderly, and immunocompromised individuals. However, rare instances have shown that hMPV can also affect other systems, such as the cardiovascular system, leading to conditions like myocarditis. CASE REPORT We describe a 68-year-old man with a medical history of diabetes, hypertension, and liver cirrhosis who presented to the Emergency Department (ED) exhibiting symptoms of fever, cough, and dyspnea.

View Article and Find Full Text PDF

Background: The Magenta Elevate is a 9-F, self-expanding, catheter-mounted pump delivered sheathed through a commercially available 10-F femoral introducer over the wire to the left ventricle (LV), providing temporary hemodynamic support up to an equivalent of normal cardiac output.

Objectives: The authors sought to assess the feasibility and outcomes of Elevate-supported high-risk percutaneous coronary intervention (HR-PCI) in a first-in-human study and study the hemodynamic impact of high-output support during prolonged interventional left main coronary artery (LM) occlusions.

Methods: In this study, 14 patients underwent Elevate-supported HR-PCI, with 8 patients undergoing 20 prolonged (39 ± 16 seconds) balloon occlusions of an unprotected LM.

View Article and Find Full Text PDF