Ultrasoft and Biocompatible Magnetic-Hydrogel-Based Strain Sensors for Wireless Passive Biomechanical Monitoring.

ACS Nano

The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Center for Mitochondrial Biology and Medicine, School of Life Science and Technology, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technology, Xi'an Key Laboratory for Biomedical Testing and High-end Equipment, State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi710049, People's Republic of China.

Published: December 2022

Implantable flexible mechanical sensors have exhibited great potential in health monitoring and disease diagnosis due to continuous and real-time monitoring capability. However, the wires and power supply required in current devices cause inconvenience and potential risks. Magnetic-based devices have demonstrated advantages in wireless and passive sensing, but the mismatched mechanical properties, poor biocompatibility, and insufficient sensitivity have limited their applications in biomechanical monitoring. Here, a wireless and passive flexible magnetic-based strain sensor based on a gelatin methacrylate/FeO magnetic hydrogel has been fabricated. The sensor exhibits ultrasoft mechanical properties, strong magnetic properties, and long-term stability in saline solution and can monitor strains down to 50 μm. A model of the sensing process is established to identify the optimal detection location and the relation between the relative magnetic permeability and the sensitivity of the sensors. Moreover, an tissue model is developed to investigate the potential of the sensor in detecting subtle biomechanical signals and avoiding interference with bioactivities. Furthermore, a real-time and high-throughput biomonitoring platform is built and implements passive wireless monitoring of the drug response and cultural status of the cardiomyocytes. This work demonstrates the potential of applying magnetic sensing for biomechanical monitoring and provides ideas for the design of wireless and passive implantable devices.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsnano.2c10404DOI Listing

Publication Analysis

Top Keywords

wireless passive
16
biomechanical monitoring
12
mechanical properties
8
monitoring
6
wireless
5
passive
5
ultrasoft biocompatible
4
biocompatible magnetic-hydrogel-based
4
magnetic-hydrogel-based strain
4
strain sensors
4

Similar Publications

Background: Magnetic resonance imaging (MRI) is a non-invasive technique that produces high-resolution images with excellent soft-tissue contrast, crucial for diagnosing various medical conditions. A key factor in MRI quality is the signal-to-noise ratio (SNR), which directly affects image clarity. To enhance SNR, passive inserts like high-permittivity dielectric pads or metamaterials are used between the tissue and coil.

View Article and Find Full Text PDF

When measuring surface biopotentials there exists a trade-off between the spacing of the recording and reference electrodes, the fidelity of the recorded signals, and its susceptibility to motion artifacts and electromagnetic interference. In this paper, we propose and demonstrate the functionality of a wearable instrumentation patch that instead of measuring referenced biopotentials, measures local bioelectric field projections using a combination of passive differential referencing circuits, active shielding and a wide-dynamic-range instrumentation amplifier. As a result, the instrumentation patch can track biopotentials with magnitudes ranging from 1μV to 5mV, and even in the presence of significant motion artifacts.

View Article and Find Full Text PDF

Almost half of the adult population in the United States have high blood pressure, however, there is no convenient way for at-home, continuous blood pressure measurements. In this paper, we investigate the potential of a wearable optical interrogator for passive, continuous and wireless transcutaneous blood pressure measurement via an implanted fiber Bragg Grating (FBG) sensor. We established that FBG signal does not get distorted while travelling through ex-vivo tissue and we have designed and validated a prototype of the optical interrogator.

View Article and Find Full Text PDF

In this work, we study the security performance of a double intelligent reflecting surface non-orthogonal multiple access (DIRS-NOMA) wireless communication system supporting communication for a group of two NOMA users (UEs) at the edge, with the existence of an eavesdropping device (ED). We also assume that there is no direct connection between the BS and the UEs. From the proposed model, we compute closed-form expressions for the secrecy outage probability (SOP) and the average security rate (ASR) for each UE.

View Article and Find Full Text PDF

The expansion of the Internet of Things (IoT) has rendered wireless passive, highly stable, and room-temperature gas sensors indispensable for sensor applications. In this work, a room-temperature surface acoustic wave (SAW) HS sensor based on a thin film of nano-mesh woven with BiS nanoribbons was successfully designed and prepared. The impact of varying inorganic salts solution ligand substitution of long-chain organic ligands of BiS films on performance was assessed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!