A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of catheter ablation of atrial fibrillation on the biomarker profile. | LitMetric

Background: Following catheter ablation for atrial fibrillation (AF), there are dynamic changes in the atrial myocardium associated with damage to and necrosis of atrial tissue and other procedure related changes in rhythm and anticoagulation. Early time-dependent changes in biomarkers of necrosis, inflammation, and coagulation have been reported. This study examines mid-term (4-8 weeks post-ablation) changes in biomarkers and explores their ability to predict AF recurrence at one-year.

Methods: Twenty-seven patients (mean age 65.4 ± 9.7 years, 30% female) undergoing catheter ablation for AF had peripheral venous blood samples obtained at the time of ablation and 4-8 weeks later. All samples were processed to obtain plasma which was frozen for subsequent analysis. Coagulation studies were performed at the Northwestern Special Hemostasis Laboratory: VWF, ADAMTS13, PAI-1, D-dimer, and TAT complexes. A commercial lab analyzed samples for CRP, cystatin C, fibrinogen, galectin, IL-6, MMP-2, myoglobin, NT-proBNP, PAI-1, TIMP-1, TIMP-2, TPA, and VWF.

Results: Significant changes were noted with higher levels of ADAMTS13 (p < 0.0001), fibrinogen (p = 0.004), MMP-2 (p = 0.0002), TIMP-2 (p = 0.003), and TPA (p = 0.001) compared to lower levels of TAT (p < 0.0001) and NT-proBNP (p = 0.0001) at follow up post-ablation. One year after ablation, AF had recurred in 11/26 (42%) of patients. None of the biomarker changes predicted the 1-year outcome, and there was no significant association with the use of warfarin versus rivaroxaban.

Conclusion: In patients undergoing catheter ablation for AF, there were significant changes in pre- vs post-ablation levels of multiple biomarkers. However, these changes were not associated with 1-year outcome of AF recurrence.

Download full-text PDF

Source
http://dx.doi.org/10.1111/pace.14640DOI Listing

Publication Analysis

Top Keywords

catheter ablation
12
ablation atrial
8
atrial fibrillation
8
changes biomarkers
8
changes
5
effects catheter
4
ablation
4
atrial
4
fibrillation biomarker
4
biomarker profile
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!