Copper laser patterning on a flexible substrate using a cost-effective 3D printer.

Sci Rep

Department of Chemistry Education, Graduate Department of Chemical Materials, Institute for Plastic Information and Energy Materials, Pusan National University, Busandaehakro 63-2, Busan, 46241, Republic of Korea.

Published: December 2022

We studied the cost effective direct laser patterning of copper (Cu) on thin polyimide substrates (PI thickness: 12.5-50 µm) using a 405 nm laser module attached to an inexpensive 3D printer. The focal length of the laser was intentionally controlled to reduce defects on patterned Cu and surface damage of PI under predetermined process conditions. The appropriate focal length was examined at various focal distances. Focal distances of - 2.4 mm and 3 mm were found for the shorter focal length (SFL) and longer focal length (LFL), respectively, compared to the actual focal length. This resulted in clean Cu line patterns without line defects. Interestingly, the SFL case had a different Cu growth pattern to that of LFL, indicating that the small difference in the laser incident angle could affect Cu precursor sintering. Cu square patterns had a lower resistivity of 70 μΩ·cm for an LFL after three or four laser scans, while the SFL showed a resistivity below 48 μΩ·cm for a one-time laser scan. The residues of the Cu precursor on PI were easily removed with flowing water and normal surfactants. However, the resistivity of the patterns decreased after cleaning. Among the scan gaps, the Cu square pattern formed at a 70 μm scan gap had the lowest sheet resistance and the least change in resistance from around 4 to 4.4 Ω/ϒ after cleaning. This result implies that the adhesion of the patterned Cu could be improved if the coated Cu precursor was well sintered under the proper process conditions. For the application of this method to bioelectronics, including biosensors, LEDs were connected to the Cu patterns on PI attached to the arm skin and worked well, even when the substrate PI was bent during power connecting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9729301PMC
http://dx.doi.org/10.1038/s41598-022-25778-yDOI Listing

Publication Analysis

Top Keywords

focal length
20
laser patterning
8
process conditions
8
focal distances
8
resistivity μΩ·cm
8
focal
7
laser
6
length
5
copper laser
4
patterning flexible
4

Similar Publications

Purpose: To quantify outer retina structural changes and define novel biomarkers of inherited retinal degeneration associated with biallelic mutations in RPE65 (RPE65-IRD) in patients before and after subretinal gene augmentation therapy with voretigene neparvovec (Luxturna).

Methods: Application of advanced deep learning for automated retinal layer segmentation, specifically tailored for RPE65-IRD. Quantification of five novel biomarkers for the ellipsoid zone (EZ): thickness, granularity, reflectivity, and intensity.

View Article and Find Full Text PDF

Unlabelled: Knowledge about trends and epidemiology of pediatric burns is useful to identify patterns, to advance medical research, and to design prevention programs and resource allocation. The aim of this study is to describe the epidemiology and trends of pediatric burns between 2009 and 2022 in the three Dutch burn centers. A secondary objective of this study is to evaluate the influence of the COVID-19 pandemic on the pattern of pediatric burns.

View Article and Find Full Text PDF

Ampullary composite gangliocytoma/neuroma and neuroendocrine tumor (CoGNET), previously called ampullary gangliocytic paragangliomas (GP) are a rare entity, with only few reported cases in the literature. This is a multicentric retrospective cohort of patients treated with endoscopy or surgery for ampullary CoGNET. A literature review of ampullary CoGNET was also performed.

View Article and Find Full Text PDF

Stable Sb exhibits a rhombohedral structure, often referred to as distorted primitive cubic, with each Sb atom having three short and three longer first neighbor bonds. However, this crystal structure can also be interpreted as being layered, putting emphasis on only three short first neighbor bonds. Therefore, temperature-dependent extended X-ray absorption fine structure (EXAFS) spectroscopy is carried out at the Sb K-edge in order to obtain more detailed information on local structural and vibrational properties.

View Article and Find Full Text PDF

Conformationally Adaptable Extractant Flexes Strong Lanthanide Reverse-Size Selectivity.

J Am Chem Soc

January 2025

Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, United States.

Chemical selectivity is traditionally understood in the context of rigid molecular scaffolds with precisely defined local coordination and chemical environments that ultimately facilitate a given transformation of interest. By contrast, nature leverages dynamic structures and strong coupling to enable specific interactions with target species in otherwise complex media. Taking inspiration from nature, we demonstrate unconventional selectivity in the solvent extraction of light over heavy lanthanides using a conformationally flexible ligand called octadecyl acyclopa (ODA).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!