A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fluorescence in situ hybridization and polymerase chain reaction to detect infections of cardiac implantable electronic devices. | LitMetric

Aims: In patients with infections of cardiac implantable electronic devices (CIEDs), the identification of causative pathogens is complicated by biofilm formations and previous antibiotic therapy. In this work, the impact of an additional fluorescence in situ hybridization (FISH), in combination with polymerase chain reaction and sequencing (FISHseq) was investigated.

Methods And Results: In 36 patients with CIED infections, FISHseq of explanted devices was performed and compared with standard microbiological cultivation of preoperative and intraoperative samples. The mean age was 61.9 (±16.2) years; 25 (69.4%) were males. Most patients (62.9%) had heart failure with reduced ejection fraction. Infections occurred as endoplastits (n = 26), isolated local generator pocket infection (n = 8), or both (n = 2); CIED included cardiac resynchronization therapy defibrillator (n = 17), implantable cardioverter defibrillator (n = 11), and pacemaker (n = 8) devices. The overall positive FISHseq detection rate was 97%. Intraoperatively, pathogens were isolated in 42 vs. 53% in standard cultivation vs. FISHseq, respectively. In 16 of 17 FISHseq-negative patients, the nucleic acid strain DAPI (4',6-diamidino-2-phenylindole) indicated inactive microorganisms, which were partially organized in biofilms (n = 4) or microcolonies (n = 2). In 13 patients in whom no pathogen was identified preoperatively, standard cultivation and FISHseq identified pathogens in 3 (23%) vs. 8 (62%), respectively. For the confirmation of preoperatively known bacteria, a combined approach was most efficient.

Conclusion: Fluorescence in situ hybridization sequencing is a valuable tool to detect causative microorganisms in CIED infections. The combination of FISHseq with preoperative cultivation showed the highest efficacy in detecting pathogens. Additional cultivation of intraoperative tissue samples or swabs yielded more confirmation of pathogens known from preoperative culture.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9935028PMC
http://dx.doi.org/10.1093/europace/euac228DOI Listing

Publication Analysis

Top Keywords

fluorescence situ
12
situ hybridization
12
polymerase chain
8
chain reaction
8
infections cardiac
8
cardiac implantable
8
implantable electronic
8
electronic devices
8
cied infections
8
standard cultivation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!