A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Combined therapy with rotational atherectomy and drug coated balloon for superficial femoral artery in-stent restenosis: safety, efficacy, and two-year results of a single center experience. | LitMetric

Background: The primary patency rate of superficial femoral artery (SFA) after percutaneous transluminal angioplasty (PTA) has improved with the use of self-expanding stents. However, occurrence of in-stent restenosis (ISR) still represents a frequent problem. Despite different studies have assessed the role of atherectomy and drug coated balloons (DCBs), no long-term data exist about combined use. The aim of this study was to evaluate safety and efficacy of combined treatment with Jetstream (Boston Scientific Corp., Marlborough, MA, USA) atherectomy and DCB for SFA intrastent restenosis (ISR) at 2-year follow-up.

Methods: 30 patients treated with PTA from November 2018 to September 2019 at Montevergine Clinic (Mercogliano, Avellino, Italy) were included in this analysis. All patients underwent PTA of SFA-ISR with Jetstream Atherectomy System followed by paclitaxel eluting balloon treatment. Patients were evaluated at 30 days, and every 3 months up to 24.

Results: Technical and procedural success was achieved in every patient. No in-hospital major adverse cardiac and cerebrovascular events occurred. No acute and sub-acute(in-hospital) procedure related complications occurred. During follow-up, 1 patient died due to stroke. Primary patency rate at 12 months was 93.4%. Primary patency rate at 24 months was 83.4%. Secondary patency rate at 24 months was 96.7%. One minor amputation, planned before treatment, was performed in the first 30 days.

Conclusions: Our data suggest that combined therapy with Rotational Atherectomy and DCBs for SFA-ISR represents a safe and effective procedure with a high rate of primary patency at 2-year follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.23736/S2724-5683.22.06214-7DOI Listing

Publication Analysis

Top Keywords

primary patency
16
patency rate
16
rate months
12
combined therapy
8
therapy rotational
8
rotational atherectomy
8
atherectomy drug
8
drug coated
8
superficial femoral
8
femoral artery
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!