Organized pancreatic and peripancreatic collections are complications of pancreatitis and should be treated when symptomatic or complicated. When feasible, the endoscopic ultrasound approach presents high efficacy and low morbidity and mortality, making it the first likely option. Among the available accessories for endoscopic drainage, the lumen-apposing metal stent can be a better option, with a low migration rate; furthermore, it allows endoscopic necrosectomy. Here, we present the case of complex walled-off necrosis treated with two lumen-apposing metal stents in the same procedure. A 41-year-old male patient with walled-off necrosis presented with delayed gastric emptying and obstruction of the main biliary duct. Magnetic resonance imaging and endoscopic ultrasound revealed two non-communicating collections. We opted for endoscopic ultrasound-guided drainage with the deployment of two simultaneous lumen-apposing metal stents: one transduodenal and the other transgastric, with clinical improvement. After three weeks, endoscopic retrograde cholangiopancreatography showed a biliary fistula communicating with the periduodenal collection, which was treated with a biliary plastic stent. An endoscopic necrosectomy was performed, and the metal stents were removed. Control magnetic resonance imaging demonstrated improvement. The patient was asymptomatic at the six-month follow-up. The treatment of symptomatic complex walled-off necrosis remains a challenge and may require multiple endoscopic approaches; moreover, surgical treatment may be necessary in case of failure. In the present report, we demonstrate that the deployment of two lumen-apposing metal stents in the same procedure is feasible when necessary as it was associated with technical success and short-term clinical success.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9716641PMC
http://dx.doi.org/10.7759/cureus.30930DOI Listing

Publication Analysis

Top Keywords

lumen-apposing metal
20
metal stents
20
walled-off necrosis
16
complex walled-off
12
endoscopic
9
simultaneous lumen-apposing
8
endoscopic ultrasound
8
endoscopic necrosectomy
8
stents procedure
8
magnetic resonance
8

Similar Publications

Background And Aims: Factors predicting the need for step-up procedures after EUS-guided drainage (EUS-FCD) of peripancreatic fluid collections (PFCs) were explored in retrospective studies restricted to Walled-Off Necrosis (WON) and Lumen Apposing Metal Stents (LAMS).

Methods: All consecutive candidates for EUS-FCD between 2020-2024 were included in a Prospective Registry of Therapeutic EUS (PROTECT, NCT04813055), with prospective monthly follow-up evaluating clinical success, adverse events and recurrences. Prospectively assessed baseline clinical and morphological factors, including the Quadrant-Necrosis-Infection (QNI) classification, were included in a stepwise logistic regression model to predict the need for step-up.

View Article and Find Full Text PDF

A lumen-apposing metal stent for diarrhea?

Gastrointest Endosc

January 2025

2nd Department of Internal Medicine - Gastroenterology and Geriatrics, University Hospital Olomouc and Faculty of Medicine, Palacký University Olomouc.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!