A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Size of atrial septal defect after balloon atrial septostomy does not correlate with immediate improvement in oxygenation. | LitMetric

Size of atrial septal defect after balloon atrial septostomy does not correlate with immediate improvement in oxygenation.

World J Pediatr Surg

Monash Heart, Monash Health, Clayton, Victoria, Australia.

Published: February 2021

Objective: Transposition of great arteries is a common cyanotic heart defect. Balloon atrial septostomy aims to improve circulatory mixing and oxygenation. Previous studies have combined infants with intact ventricular septum and those with ventricular septal defect. Additionally, the septostomy was performed much later after birth. The objectives were to ascertain any correlation between the atrial septal defect size and oxygenation, before and after septostomy, as well the change in parameters pre-post procedure.

Methods: We performed an audit of the last 10 years of clinical and echocardiographic data (2010-2020) for infants with transposition of great arteries with intact ventricular septum. A pediatric cardiologist, masked to clinical data, reviewed the images.

Results: Our study of 25 infants with transposition of great arteries with intact ventricular septum noted that the procedure was performed at a median [interquartile range (IQR)] of 3 (2, 4) hours after birth. Prostaglandin was administered to the majority of infants [20/25 (80%)]. While significant increases in partial pressure of oxygen (24±5 vs 40±6 mmHg, p<0.001) and preductal oxygen saturations (67%±18% vs 81%±11%, p=0.003) were noted, and while the atrial septal defect increased in size from 1.8±0.6 vs 4.8±0.7 mm (p<0.001), no correlation was noted between atrial septal defect size and oxygen saturations.

Conclusions: In our study of infants with transposition of great arteries and intact ventricular septum managed with balloon atrial septostomy, no correlation was noted between the atrial septal defect size and oxygen saturations. Pulmonary vascular resistance and pulmonary blood flow may be important physiological variables determining oxygenation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9717414PMC
http://dx.doi.org/10.1136/wjps-2020-000224DOI Listing

Publication Analysis

Top Keywords

septal defect
12
transposition great
12
great arteries
12
intact ventricular
12
ventricular septum
12
atrial septal
8
defect balloon
8
balloon atrial
8
atrial septostomy
8
infants transposition
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!