Background: Anderson-Fabry disease (AFD) is an X-linked inherited lysosomal disease caused by a defect in the gene encoding lysosomal enzyme α-galactosidase A (GLA). Atrio-ventricular (AV) nodal conduction defects and sinus node dysfunction are common complications of the disease. It is not fully elucidated how frequently AFD is responsible for acquired AV block or sinus node dysfunction and if some AFD patients could manifest primarily with spontaneous bradycardia in general population. The purpose of study was to evaluate the prevalence of AFD in male patients with implanted permanent pacemaker (PM).
Methods: The prospective multicentric screening in consecutive male patients between 35 and 65 years with implanted PM for acquired third- or second- degree type 2 AV block or symptomatic second- degree type 1 AV block or sinus node dysfunction was performed.
Results: A total of 484 patients (mean age 54 ± 12 years at time of PM implantation) were enrolled to the screening in 12 local sites in Czech Republic. Out of all patients, negative result was found in 481 (99%) subjects. In 3 cases, a GLA variant was found, classified as benign: p.Asp313Tyr, p.D313Y). Pathogenic GLA variants (classical or non-classical form) or variants of unclear significance were not detected.
Conclusion: The prevalence of pathogenic variants causing AFD in a general population sample with implanted permanent PM for AV conduction defects or sinus node dysfunction seems to be low. Our findings do not advocate a routine screening for AFD in all adult males with clinically significant bradycardia.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijcard.2022.11.062 | DOI Listing |
Pacing Clin Electrophysiol
December 2024
Division of Cardiology, Department of Medicine, Weill Cornell Medicine, New York Presbyterian Hospital, New York, USA.
Leadless pacing technology now includesdedicated atrial helix-fixation leadless pacemakers (LPs), expanding theapplication of leadless devices for patients with sinus node dysfunction andatrioventricular block during sinus rhythm. This first reportedcase-series of atrial LPs describes and discusses the potential use-casescenarios of recently approved helix-fixation atrial LPs. The article highlights important concepts regarding their use, including implantationtechniques, programming, battery conservation, and the low rate of progressionof AV block in patients implanted with AAI(R) pacemakers.
View Article and Find Full Text PDFPacing Clin Electrophysiol
December 2024
Electrophysiology and Cardiac Pacing Unit, Pellegrini Hospital, Naples, Italy.
Reel's syndrome (RS) is an unusual cause of pacemaker lead dislodgement. We present the case of a 59-year-old female patient with Down syndrome (DS) implanted with a dual-chamber endovascular pacemaker due to symptomatic sinus node disfunction, reporting several syncopal episodes in last days and showing abnormal electrical parameters at the 2-months follow-up due to RS. The malfunctioning device was removed and an endocardial leadless pacing system was implanted.
View Article and Find Full Text PDFCell Rep
December 2024
Precision Cardiology Laboratory, The Broad Institute, Cambridge, MA 02142, USA; Cardiovascular Research Center, Massachusetts General Hospital, Boston, MA 02114, USA; Cardiology Division, Massachusetts General Hospital, Boston, MA 02114, USA. Electronic address:
We sought to characterize cellular composition across the cardiovascular system of the healthy Wistar rat, an important model in preclinical cardiovascular research. We performed single-nucleus RNA sequencing (snRNA-seq) in 78 samples in 10 distinct regions, including the four chambers of the heart, ventricular septum, sinoatrial node, atrioventricular node, aorta, pulmonary artery, and pulmonary veins, which produced 505,835 nuclei. We identified 26 distinct cell types and additional subtypes, with different cellular composition across cardiac regions and tissue-specific transcription for each cell type.
View Article and Find Full Text PDFNeurol Sci
December 2024
Division of Cardiology, Cardio-Thoracic Department, University Hospital of Verona, Verona, Italy.
Background: Implantable loop recorders (ILRs) have been shown to significantly improve the detection of atrial fibrillation (AF) in patients with embolic stroke of undetermined source (ESUS). The incidence and characterization of bradyarrhythmias in this subset of patients is still unknown.
Methods: All consecutive patients who received ILRs, after an ESUS, between March 2015 and December 2022 in our Center were retrospectively enrolled and analyzed.
Cardiol Rev
November 2024
Department of Cardiovascular Medicine, Cardiovascular Analytics Group, Islamabad, Pakistan.
A fraction of patients (approximately 10%) undergoing heart transplantation require permanent pacemaker (PPM) implantation due to sinus node dysfunction or atrioventricular block, occurring either shortly after surgery or later. The incidence of PPM implantation has declined to less than 5% with the introduction of bicaval anastomosis transplantation surgery. Pacing dependency during follow-up varies among recipients.