Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Extracorporeal life support is an advanced therapy that circulates blood through an extracorporeal oxygenator, performing gas exchange outside the body. However, its use is limited by severe complications, including bleeding, clotting, and hemolysis. Semiconductor silicon-based membranes have emerged as an alternative to traditional hollow-fiber semipermeable membranes. These membranes offer excellent gas exchange efficiency and the potential to increase hemocompatibility by improving flow dynamics. In this work, we evaluate two next-generation silicon membrane designs, which are intended to be mechanically robust and efficient in gas exchange, while simultaneously reducing fabrication complexity. The "window" design features 10 µm pores on one side and large windows on the back side. The "cavern" design also uses 10 µm pores but contains a network of interconnected buried caverns to distribute the sweep gas from smaller inlet holes. Both designs were shown to be technically viable and able to be reproducibly fabricated. In addition, they both were mechanically robust and withstood 30 psi of transmembrane pressure without breakage or bubbling. At low sweep gas pressures, gas transfer efficiency was similar, with the partial pressure of oxygen in water increasing by 10.7 ± 2.3 mmHg (mean ± standard deviation) and 13.6 ± 1.9 mmHg for the window and cavern membranes, respectively. Gas transfer efficiency was also similar at higher pressures. At 10 psi, oxygen tension increased by 16.8 ± 5.7 mmHg (window) and 18.9 ± 1.3 mmHg (cavern). We conclude that silicon membranes featuring a 10 µm pore size can simplify the fabrication process and improve mechanical robustness while maintaining excellent efficiency.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10544-022-00639-7 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!