Full-arch implant reconstructions are being utilized in clinical practice today. Very often these prostheses are prosthetically driven, but not periodontally maintainable. Often the patient presents to the general practitioner with a failing implant reconstruction, where several fixtures need to be removed and others are maintainable. The article presents a case report where a removable prosthesis is used as a transitional appliance during the retreatment of the case. A removable complete overdenture prosthesis using attachments was used to establish proper occlusion and function, prevent loading on the guided bone regeneration sites, and to assist in fabrication of a stable guide for implant placement. The staged approach facilitated laser periodontal therapy on the remaining fixtures, and allowed proper oral hygiene instruction and assessment of the patient's ability to clean the remaining fixtures properly. Although the potential to treat this case with transitional implants or immediate load fixtures was discussed, the risk versus benefit scenario favored a removable prosthesis with attachments. Success required proper communication between the surgeon, restorative dental practitioner, laboratory, and patient. (Quintessence Int 2023;54:126-132; doi: 10.3290/j.qi.b3648969).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3290/j.qi.b3648969 | DOI Listing |
Cureus
November 2024
Department of Removable Prosthodontics, Syrian Arab Republic Damascus University Faculty of Dental Medicine, Damascus, SYR.
Background: Determining the distal cantilever length in All-on-Four (All-on-4) implant-supported prostheses is a major factor in the long-term success of these prostheses. The difference in mechanical properties of materials used in the fabrication of these prostheses, such as polyether ether ketone (PEEK), may have an impact on the determination of the cantilever length that best distributes stress.
Aim: To study the distribution of stress in All-on-4 mandibular prostheses in the bone, implants, and framework according to difference cantilever length in PEEK prosthetic framework using three-dimensional finite element analysis.
J Prosthodont
December 2024
Schulich School of Medicine and Dentistry, Department of Dentistry, Western University, London, Canada.
Purpose: To compare digitally fabricated complete dentures to conventionally fabricated dentures using patient- and clinician-reported outcome measures.
Methods: This review was structured according to PRISMA guidelines with the protocol registered in the PROSPERO database (CRD42024526069). An electronic search of the databases with a defined search strategy was completed within PubMed/MEDLINE and Web of Science from January 2000 to March 2024.
J Med Life
October 2024
Department of Removable Prosthodontics, Faculty of Dental Medicine, University of Monastir, Monastir, Tunisia.
Amelogenesis imperfecta refers to a group of hereditary diseases that affect dental enamel, often leading to a wide range of clinical manifestations and aesthetic concerns. This case report describes a female patient diagnosed with amelogenesis imperfecta associated with a skeletal open bite. The treatment approach was multidisciplinary.
View Article and Find Full Text PDFClin Oral Investig
December 2024
Dental School, Department of Prosthodontics, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
Objectives: Clinical data on the performance of double-crown-retained removable dental prostheses (dcRDPs), especially beyond university studies, are rare. The objective of this retrospective clinical study was to evaluate the survival and complication-freeness probabilities of dcRDPs and to identify risk factors for failure and complications in a dental practice setting.
Materials And Methods: Anonymized practice data of 174 patients (56.
Stomatologiia (Mosk)
December 2024
Mongolian State University of Medical Sciences, Ulan-Bator, Mongolia.