Purpose: A longer stent is associated with adverse events after percutaneous coronary intervention (PCI). However, little information is available on the relationship between stent length and periprocedural prognosis in patients with ST segment elevation myocardial infarction (STEMI). We aimed to assess the target vessel stent length influence on angiographic outcomes and in-hospital major adverse cardiovascular event (MACE) during primary PCI in patients with STEMI.

Patients And Methods: This single-center retrospective observational study included 246 patients with STEMI admitted to the Zhejiang Provincial People's Hospital between January 2019 and December 2021, who underwent primary PCI and successful stent implantation. The exclusion criteria included left main lesion, multiple diseased vessel-stenting, bleeding disorders, contrast allergy, and incomplete data. Patients were divided into two groups based on the median stents length: group A (≤29 mm, n=125) and group B (>29mm, n=121). Periprocedural outcomes were slow flow/no-reflow (SF-NR) and in-hospital MACE, which included acute heart failure, malignant arrhythmia, cardiovascular death, non-fatal stroke, non-fatal myocardial infarction, and urgent revascularization. Multivariate logistic analyses were used to explore the correlation between stent length and SF-NR.

Results: A total of 246 patients (82.9% males) with a mean age of 59.9±12.6 years were included in the analysis. The incidence of SF-NR was significantly higher in group B than in group A (36.4% vs 23.2%, p=0.024). However, the in-hospital MACE incidence rate was similar between the two groups (7.2% vs 7.4%, p=0.943). Multivariate logistic regression analysis showed that stent length and diameter, and peak troponin I level were independent risk factors for SF-NR.

Conclusion: Excessive stent length is an independent risk factor for SF-NR, without any significant influence on the risk of MACE during hospitalization.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9717423PMC
http://dx.doi.org/10.2147/CIA.S389302DOI Listing

Publication Analysis

Top Keywords

stent length
24
myocardial infarction
12
length periprocedural
8
periprocedural outcomes
8
percutaneous coronary
8
coronary intervention
8
patients segment
8
segment elevation
8
elevation myocardial
8
primary pci
8

Similar Publications

Background: The prevalence of coronary chronic total occlusion (CTO) in coronary angiography (CAG) has risen with ageing populations, along with the expansion of CTO percutaneous coronary interventions (CTO-PCI). However, CTO-PCI encounters challenges such as undersized stents, dissection risks, and limited access to intravascular imaging (IVI), particularly in regions with limited health budgets. This study introduces the 'GIVE IT TIME TO SOBER UP - GITSU strategy', a two-session CTO-PCI approach where Thrombolysis in Myocardial Infarction (TIMI-3) antegrade flow is achieved without stent placement in the first session.

View Article and Find Full Text PDF

Background And Aim: Although long self-expandable metal stent (SEMS) with a sufficient intragastric portion is typically preferred for endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), this design can complicate endoscopic re-intervention for recurrent biliary obstruction (RBO). We evaluated the efficacy and safety of endoscopic re-intervention for RBO through the stent after EUS-HGS using a novel partially covered SEMS with an anchoring flange.

Methods: The partially covered SEMS was designed with a intrahepatic uncovered portion measuring 1.

View Article and Find Full Text PDF

Background And Aims: When dealing with severely calcified lesions in endovascular therapy (EVT) for lower extremity artery disease (LEAD), navigating through severely calcified chronic total occlusion (CTO) using hard-tip guidewires can be challenging. To address this issue, we employed a novel highly intensive penetration (HIP) technique. This technique involves modifying the tail of a 0.

View Article and Find Full Text PDF

Objectives: To compare the safety and efficacy of debulking devices, including directional atherectomy (DA) and excimer laser atherectomy (ELA), when combined with drug-coated balloons (DCB) for treating de novo femoropopliteal atherosclerotic obliterans (ASO). Additionally, to evaluate the long-term outcomes and application status of these different debulking devices.

Methods: Clinical data were collected from patients with femoropopliteal ASO who underwent combined debulking and DCBs at the Vascular Surgery Department of Xuanwu Hospital, Capital Medical University, China, between January 2018 and January 2023.

View Article and Find Full Text PDF

Objective: To evaluate the safety and efficacy of excimer laser ablation (ELA) combined with drug-coated balloon(DCB)in the treatment of Chronic limb-threatening ischemia (CLTI) patients with de novo and in-stent restenosis (ISR) lesions in the femoropopliteal artery.

Methods: A retrospective, single-center analysis was performed on data collected between January 2017 and December 2021. The study included CLTI patients who underwent treatment with ELA combined with DCB for de novo and ISR lesions in the femoropopliteal artery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!