The recirculation of venovenous extracorporeal membrane oxygenation (VV-ECMO) will decrease the efficiency of respiratory support. We report a patient with refractory severe acute respiratory distress syndrome (ARDS). Even with the support of ECMO and mechanical ventilation (MV), it is still difficult to correct hypoxemia. In this case, we placed a balloon catheter above the ECMO drainage cannula in inferior vena cava (IVC), and then occlusion the IVC with the water-filled balloon. After the occlusion, the patient's hypoxemia was quickly improved, and angiography proved that the recirculation has been significantly reduced. In this case, IVC occlusion technology greatly reduces recirculation. Its advantages lie in simple operation, low cost, short term safety, which probably act as an innovative method to reduce recirculation.

Download full-text PDF

Source
http://dx.doi.org/10.1177/02676591221144171DOI Listing

Publication Analysis

Top Keywords

reduce recirculation
8
recirculation venovenous
8
venovenous extracorporeal
8
extracorporeal membrane
8
membrane oxygenation
8
inferior vena
8
vena cava
8
ivc occlusion
8
recirculation
5
novel strategy
4

Similar Publications

Globally, various policies are being implemented to phase out plastic, and South Korea has set targets to reduce waste and increase recycling rates by 2030. Concerns about managing microplastic pollution are growing. Most advanced research has primarily focused on aquatic ecosystems.

View Article and Find Full Text PDF

Computational exploration of injection strategies for improving medicine distribution in the liver.

Comput Biol Med

December 2024

Faculty of Chemical & Petroleum Engineering, University of Tabriz, Tabriz, Iran. Electronic address:

Background And Objectives: The liver, a vital metabolic organ, is always susceptible to various diseases that ultimately lead to fibrosis, cirrhosis, acute liver failure, chronic liver failure, and even cancer. Optimal and specific medicine delivery in various diseases, hepatectomy, shunt placement, and other surgical interventions to reduce liver damage, transplantation, optimal preservation, and revival of the donated organ all rely on a complete understanding of perfusion and mass transfer in the liver. This study aims to simulate the computational fluid dynamics of perfusion and the temporal-spatial distribution of a medicine in a healthy liver to evaluate the hemodynamic characteristics of flow and medicine transport with the purpose of more effective liver treatment.

View Article and Find Full Text PDF

Circular Shunt: A Loop Not to Be Ignored.

J Cardiothorac Vasc Anesth

December 2024

Department of Cardiothoracic Surgery, National Heart Center, Royal Hospital, Muscat, Oman.

A circular shunt, initially described by Shone et al. in 1962, refers to abnormal blood recirculation through complete intracardiac or intra- and extracardiac communications, bypassing the capillary beds. This pathophysiological condition is most commonly associated with complex congenital heart defects, such as Ebstein's malformation, pulmonary atresia, Gerbode defect, and so on.

View Article and Find Full Text PDF

Synergistic activation of reburned char for ultra-low NOx emissions using flue gas recirculation and natural gas in a 10 kW furnace.

J Environ Manage

December 2024

Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore, 117575, Singapore. Electronic address:

The technology of powdered coal injection with recirculating flue gas and natural gas conditioning for reburning represents an advanced and innovative approach to enhancing the efficiency of coal powder reburning. By consuming excess oxygen in the recirculated flue gas, natural gas fosters an environment enriched with reducing agents, which stimulates the reactivity of reburning coal powder and augments its effectiveness in reducing nitrogen oxides (NO). This technology has been comprehensively investigated through experiments conducted in a segmented multi-reactor flow system, simulating conditions akin to those in industrial boilers.

View Article and Find Full Text PDF
Article Synopsis
  • The study developed two types of reactors, the SADR and WSMDR, for removing nitrate from water, achieving denitrification rates of 66-114 g-N/(m·d) and 70-104 g-N/(m·d), respectively.
  • Sulfate production in both reactors was lower than theoretical predictions, with the SADR producing 5.5-5.9 mg SO/mg reduced N and the WSMDR producing 3.2-4.5 mg SO/mg reduced N, while no sulfide was emitted.
  • Key microorganisms like Chlorobium and Thiobacillus were identified as crucial for nitrate reduction, and improved denitrification performance was linked to a higher abundance of functional genes
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!