Background And Aims: In patients with unresectable malignant biliary obstruction (MBO), endoscopic drainage with a self-expandable metal stent (SEMS) is a well-established treatment, but stent patency is limited. This study aimed to evaluate the efficacy of in-stent radiofrequency ablation (IS-RFA) followed by uncovered SEMS placement for the management of occluded SEMSs.
Methods: From 2016 to 2020, 48 patients with recurrent biliary obstruction due to tumor ingrowth or overgrowth after SEMS placement for pancreatobiliary cancer in 3 tertiary hospitals were analyzed. For distal MBO, patients in the RFA group were treated with IS-RFA and uncovered SEMS placement, and those in the control group were treated with uncovered SEMS placement alone. Patients in both groups were matched on the basis of propensity scores in a 1:1 ratio.
Results: The median time to recurrent biliary obstruction (TRBO) was 117 days in the RFA group and 82.5 days in the control group (P = .029). No significant differences in median overall survival were detected between the 2 groups (170 days vs 72 days; P = .902). No significant adverse events were reported after the second SEMS placement in either group, but 2 cases of mild cholangitis were reported in the control group. Ablation was interrupted in 5 patients (35.7%) of the RFA group owing to in-stent contact, but sufficient ablative energy was delivered in the majority of the patients (92.9%) after IS-RFA was repeated in the same session.
Conclusions: IS-RFA followed by an uncovered SEMS is safe and feasible and may improve TRBO as a stent revision for occluded SEMSs in pancreatobiliary cancer.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.gie.2022.11.017 | DOI Listing |
Surg Endosc
January 2025
Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Background And Aims: Self-expandable metal stents (SEMS) are effective in alleviating malignant colorectal obstruction. However, bowel perforation following SEMS placement remains a significant concern, as it can adversely affect oncological outcomes. This study aimed to evaluate the recurrence and overall survival rates associated with SEMS-related bowel perforations.
View Article and Find Full Text PDFInt J Surg Oncol
January 2025
Department of Surgical Oncology, Dr Bhubaneswar Borooah Cancer Institute, Guwahati, India.
Esophageal cancer is the sixth most common cancer in India with a incidence of around 4.5%. Dysphagia is the primary manifestation of advanced esophageal cancer in 80%-90% of patients.
View Article and Find Full Text PDFTech Coloproctol
December 2024
Department of Colorectal Surgery, Changhai Hospital, Naval Medical University, Shanghai, 200433, China.
Objective: To investigate the optimal interval between self-expanding metal stent (SEMS) placement and radical surgery in patients with obstructive colorectal cancer.
Method: In this study, a retrospective research design was used to select 125 patients with obstructive colorectal cancer who underwent colonoscopic SEMS placement with subsequent radical surgery between February 2011 and November 2022 at Shanghai Changhai Hospital. In addition, their clinical data and therapeutic efficacy were examined.
Surg Endosc
December 2024
Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Background And Aims: Self-expanding metal stents (SEMSs) are effective for symptom palliation in patients with esophageal obstruction. However, their placement can lead to adverse events such as stent migration and restenosis. A novel fully covered SEMS (FCSEMS) with antimigration properties has been developed to address these issues.
View Article and Find Full Text PDFJ Clin Med
October 2024
Department of Gastroenterology and Hepatology, Yokohama City University, Yokohama 236-0004, Japan.
Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) often requires fistula dilation owing to the placement of a large diameter of the delivery stent. The recently developed delivery devices, which are as thin as 5.9/6.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!