Objectives: Organic polymers are materials widely used in our daily lives, such as daily necessities, foods, and medicines. There have been reports recently that cross-linked polyacrylic acid (CL-PAA) can possibly cause serious lung disease. We investigated whether intratracheal instillation of CL-PAA causes pulmonary disorder in rats.

Methods: Male F344 rats were administered low (0.2 mg/rat) and high (1.0 mg/rat) doses of CL-PAA intratracheally and were dissected 3 days, 1 week, 1 month, 3 months, and 6 months after exposure to examine inflammatory and fibrotic responses in the lungs. Only the high-dose specimens were subjected to ultrasonic dispersion treatment of the administered material.

Results: There was a dose-dependent increase in the total cell count, neutrophil count, neutrophil percentage, lactate dehydrogenase (LDH), surfactant protein D (SP-D), cytokine-induced neutrophil chemoattractant (CINC)-1 and CINC-2 values in bronchoalveolar lavage fluid (BALF) from 3 days to at least 3 months after intratracheal administration of CL-PAA. Heme oxygenase-1 (HO-1) in lung tissue was also persistently elevated from 3 days to 6 months after exposure. Alkaline phosphatase (ALP) in BALF was elevated at 3 days and 1 month after exposure only in the high-dose group. Histopathological findings in lung tissue showed inflammatory and fibrotic changes from 3 days after administration, and we observed obvious inflammatory changes for up to 3 months and fibrotic changes for up to 6 months.

Conclusion: Intratracheal administration of CL-PAA induced persistent neutrophilic inflammation and fibrosis in the rats' lungs, suggesting that CL-PAA may have inflammogenic and fibrogenic effects.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9717705PMC
http://dx.doi.org/10.1002/1348-9585.12369DOI Listing

Publication Analysis

Top Keywords

pulmonary disorder
8
cross-linked polyacrylic
8
polyacrylic acid
8
6 months exposure
8
inflammatory fibrotic
8
count neutrophil
8
intratracheal administration
8
administration cl-paa
8
lung tissue
8
elevated 3 days
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!