A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Stress distribution in pediatric zirconia crowns depending on different tooth preparation and cement type: a finite element analysis. | LitMetric

Background: In clinical settings, tooth preparation for prefabricated zirconia crowns (PZCs) in the primary dentition varies widely. However, knowledge about the biomechanical behavior of PZCs in various clinical settings is limited. This study was conducted to evaluate the biomechanical behavior of PZCs in different clinical settings using 3-dimensional finite element analysis.

Methods: 3-dimensional models of the PZC, cement, and tooth with six different conditions were simulated in primary molar teeth, incorporating cement thickness (100, 500, and 1000 μm) and cement type (resin-modified glass ionomer cement and resin cement). A total of 200 N of occlusal force was applied to the models, both vertically and obliquely as representative cases. A general linear model univariate analysis with partial eta-squared (ηp) was performed to evaluate the relative effects of the variables.

Results: The overall stress of tooth was increased as the cement space increases under oblique loading. The von Mises stress values of the resin cements were significantly higher than those of the resin-modified glass ionomer cements for all cement thicknesses (p < .05). The effect size of the cement type (η = .519) was more dominant than the cement thickness (η = .132) in the cement layer.

Conclusions: Within the limits of this study, cement type has a greater influence on the biomechanical behavior of PZCs than cement thickness.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9714224PMC
http://dx.doi.org/10.1186/s12903-022-02596-2DOI Listing

Publication Analysis

Top Keywords

clinical settings
12
zirconia crowns
8
tooth preparation
8
cement
8
cement type
8
finite element
8
biomechanical behavior
8
behavior pzcs
8
pzcs clinical
8
resin-modified glass
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!