Evaluation of OrthoChromic OC-1 films for photon radiotherapy application.

J Radiat Res

Department of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Ave, New York, New York 10065, USA.

Published: January 2023

A new film dosimetry system consists of the new OrthoChromic™ OC-1 film, and a novel calibration procedure was evaluated. Two films, C1 and C2, were exposed simultaneously using the 6FFF beam with a step-wedge pattern of five steps ranging from 590 to 3000 cGy. C1 was used for calibration, and C2 was used for calibration curve validation. The second scan of C2 was done by rotating the film by 90-deg. To evaluate the effectiveness of the non-uniform scanner response correction with the new system, a film was exposed to a 20 × 20 cm2 field. The beam profile measured with the film was compared to the IBA cc04 measurements in water. Films were irradiated to characterize the energy response, dynamic range and temporal growth effect. Open (MLC-defined) and clinical fields were radiated to evaluate the overall performance of the new system. The new calibration procedure was validated with an average dose difference of 1.6% and a gamma (2%,2 mm) passing rate of 100%. With C2 scanned 90-deg rotated, the average dose difference was 1.3%. The average difference between cc04 and film was 0.4%. The St between films and diode/cc04 were within -0.3% difference for 1 × 1 to 14 × 14 cm2 and -2.8% for 0.5 × 0.5 cm2. For clinical fields, the average gamma (3%,2 mm) was 98.8%. These results were consistent with EBT3 film and MapCheck measurements with a dose > 400 cGy. The results have shown that the OC-1 film system can achieve accurate results for QA measurements, but more considerable uncertainty was observed within the low dose range.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9855338PMC
http://dx.doi.org/10.1093/jrr/rrac080DOI Listing

Publication Analysis

Top Keywords

film
8
oc-1 film
8
calibration procedure
8
clinical fields
8
average dose
8
dose difference
8
evaluation orthochromic
4
orthochromic oc-1
4
films
4
oc-1 films
4

Similar Publications

Weighted Echo State Graph Neural Networks Based on Robust and Epitaxial Film Memristors.

Adv Sci (Weinh)

January 2025

College of Physics Science & Technology, School of Life Sciences, Institute of Life Science and Green Development, Key Laboratory of Brain-Like Neuromorphic Devices and Systems of Hebei Province, Hebei University, Baoding, 071002, China.

Hardware system customized toward the demands of graph neural network learning would promote efficiency and strong temporal processing for graph-structured data. However, most amorphous/polycrystalline oxides-based memristors commonly have unstable conductance regulation due to random growth of conductive filaments. And graph neural networks based on robust and epitaxial film memristors can especially improve energy efficiency due to their high endurance and ultra-low power consumption.

View Article and Find Full Text PDF

An electro- and optically favorable quaternary nanocomposite film was produced by solution-casting nickel oxide nanoparticles (NiO NPs) into polyvinyl alcohol (PVA), polyvinyl pyrrolidone (PVP), and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT/PSS). Based on transmission electron microscopy (TEM) and X-ray diffraction (XRD) observations, the synthesized NiO NPs have a cubic phase and a diameter between 10 and 45 nm. The complexity and interactions observed through XRD patterns, UV-visible spectra, and FTIR measurements suggest that the NPs are not just dispersed within the polymer matrix, but are interacting with it, leading to enhanced dielectric properties and AC electrical conductivity.

View Article and Find Full Text PDF

Despite recent advancements in organic photovoltaics (OPVs), further improvements in power conversion efficiency (PCE) and device lifetime are necessary for commercial viability. Strategies such as optimizing the molecular orientation and minimizing the charge traps of organic films are particularly effective in enhancing photovoltaic performance. In this study, we successfully utilized vacuum electrospray deposition (VESD) to achieve favourable face-on stacking geometries while preserving the integrity of the interfaces in poly(3-hexylthiophene-2,5-diyl) (P3HT): [6,6]-phenyl-C-butyric acid methyl ester (PCBM) bulk heterojunction (BHJ) films.

View Article and Find Full Text PDF

Background: Overexpression of tear matrix metalloproteinases-9 (MMP-9) on the ocular surface tissues has been reported to result in ocular surface damage. MMP-9 levels in tears have been listed as one of many tools for confirming dry eye disease (DED).

Objective: This investigation aimed to compare MMP-9 levels and ocular surface parameters in diabetic patients with and without DED.

View Article and Find Full Text PDF

Stress-induced self-assembly of hierarchically twisted stripe arrays.

Sci Bull (Beijing)

December 2024

Department of Chemistry, Laboratory of Advance Materials, Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, State Key Laboratory of Molecular Engineering of Polymers, and iChEM, Fudan University, Shanghai 200433, China. Electronic address:

Hierarchical organization is prevalent in nature, yet the artificial construction of hierarchical materials featuring asymmetric structures remains a big challenge. Herein, we report a stress-induced self-assembly strategy for the synthesis of hierarchically twisted stripe arrays (HTSAs) with mesoporous structures. A soft and thin mesostructured film assembled by micelles and TiO oligomers is the prerequisite.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!