Introduction: Malalignment and resulting complications are major challenges in total knee arthroplasty (TKA) which patient-specific instrumentation (PSI) is proposed to alleviate. Previous PSI meta-analyses of TKA outcomes typically do not differentiate between PSI systems and assess relatively few outcomes, so the value of their findings is limited. VISIONAIRE cutting guides (Smith + Nephew Inc., Memphis, TN, USA) is a PSI system based on preoperative magnetic resonance and X-ray imaging. A systematic literature review (SLR) and meta-analysis, focussed specifically on VISIONAIRE, were conducted to assess TKA accuracy, intraoperative outcomes, and postoperative outcomes, compared with conventional instrumentation (CI).

Materials And Methods: The SLR was performed using PubMed, Embase, and Google Scholar databases to identify relevant studies published until March 2022. Depending on statistical heterogeneity, meta-analyses were performed for outcome measures with fixed effect (I < 50%) or random-effects models (I ≥ 50%). Dichotomous outcomes were reported as odds ratios and continuous outcomes were reported as mean differences. Descriptive analyses were performed for outcomes not amenable to meta-analysis.

Results: Outcomes for VISIONAIRE versus CI were reported in 25 studies. Compared with CI, VISIONAIRE reduced odds of mechanical outliers by 40% (p < 0.0001), with no statistically significant differences in odds of overall coronal, sagittal, or rotational plane component outliers. VISIONAIRE improved surgical efficiency (operating room, turnover, and tourniquet times reduced by 7.3% (p = 0.02), 42% (p = 0.022), and 15.9% (p = 0.01), respectively), lowering the odds of blood transfusion by 53% (p = 0.01) and shortening patients' hospital stays (11.1% reduction; p < 0.0001). There were no significant differences between groups in incidence of postoperative complications and (descriptively analyzed) return-to-function outcomes.

Conclusion: Options for PSI in TKA differ substantially, and it is important to assess the outcomes of individual systems. The current findings suggest that VISIONAIRE guides can lead to improved alignment accuracy and surgical efficiency compared with CI, without compromising postoperative safety and return-to-function outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10293358PMC
http://dx.doi.org/10.1007/s00402-022-04698-6DOI Listing

Publication Analysis

Top Keywords

patient-specific instrumentation
8
conventional instrumentation
8
total knee
8
knee arthroplasty
8
systematic literature
8
literature review
8
outcomes
5
comparison clinical
4
clinical outcomes
4
outcomes visionaire
4

Similar Publications

Background: Patellar fractures present challenges in treatment, with traditional methods often leading to complications such as loss of reduction and implant failure. This study aimed to compare a novel suture fixation technique with the traditional tension band method using finite element analysis.

Methods: CT images of a healthy 35-year-old male were used to construct 3D patellar models.

View Article and Find Full Text PDF

Purpose: The aim of the study was to determine preoperative patient- and fracture-related risk factors for estimating the risk of fracture sequelae after surgically treated proximal humerus fractures (PHF) using locking plate osteosynthesis. The purpose was to develop a fracture sequelae risk score as an additional tool to facilitate the treatment strategy for PHF.

Methods: All patients with PHF who underwent surgery with locking plate osteosynthesis were included.

View Article and Find Full Text PDF

Alternatives for exhausted dialysis access.

Semin Vasc Surg

December 2024

Department of Surgery, Division of Vascular and Endovascular Surgery, Duke University Medical Center, Durham, NC. Electronic address:

Hemodialysis (HD) access failure is a frequent problem encountered by vascular surgeons. As treatment of end-stage renal disease improves and patients live longer on HD, eventual exhaustion of traditional upper extremity HD access is common. Efforts to preserve and maintain these accesses are essential.

View Article and Find Full Text PDF

Purpose: Computer-aided design (CAD) and computer-aided manufacturing (CAM) techniques have paved the way for single-step resections and cranio-orbital reconstructions with patient specific implants in spheno-orbital tumors. Here, we present our interdisciplinary maxillofacial and neurosurgical workflow and a case series of patients treated with this integrated approach.

Methods: Patients, who underwent single-step resection of benign spheno-orbital tumors and cranio-orbital reconstruction with polyetheretherketone (PEEK) patient specific implants (PSI) from 2019 to 2024 in our institution were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!