Thermoluminescence dosimetry is considered as an effective method in estimating the absorbed doses to organs in different imaging modalities. The present study focuses on dosimetry in dual-energy X-ray absorptiometry scans, for patients, and phantoms in various imaging centres. The cubical LiF (Mg, Ti) thermoluminescence dosemeters were inserted inside the holes of the Rando phantom slabs, to measure the absorbed dose to different organs in the whole body and lumbar scans. According to the results the maximum entrance skin dose was found to be 202.06 μGy for Hologic discovery W, which uses the fan beam scanning mode. The Norland XR-800 device took the scans with a much lower dose, as it uses the pencil beam for scanning the patients. The results of the study show that the radiation beam type, patient thickness, imaging technique and scan time may affect the radiation dose received by patient.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/rpd/ncac233 | DOI Listing |
Cancer Manag Res
January 2025
School of Physics, Universiti Sains Malaysia, Penang, 11800 Gelugor, Malaysia.
Introduction: Breast cancer is a significant worldwide health issue, particularly in Jordan, where early detection via mammography is essential for effective disease management. Despite the little radiation risk associated with mammography, it is crucial to monitor radiation exposure to guarantee patient safety. This study intends to assess skin entrance exposure and compute the Mean Glandular Dose (MGD) in mammography units to determine adherence to established criteria and pinpoint areas for enhancement.
View Article and Find Full Text PDFExp Dermatol
January 2025
Department of Medicine and Division of Clinical Immunology, Icahn School of Medicine at Mount Sinai, New York, New York, USA.
Merkel cell carcinoma (MCC) is a skin cancer that arises due to either Merkel cell polyomavirus infection (MCPyV) or ultraviolet (UV) radiation exposure, presenting primarily in the head and neck region of fair-skinned males. The recent success of PD-(L)1 immune checkpoint inhibitors (ICIs) in locally advanced/metastatic MCC, with an objective response rate (ORR) around 50% and improved survival, as a first-line treatment has moved ICIs to the forefront of therapy for MCC and generated interest in identifying biomarkers to predict clinical response. The MCC tumour microenvironment (TME) contains various components of the adaptive and innate immune system.
View Article and Find Full Text PDFDiagnostics (Basel)
November 2024
Faculty of Applied Science, Uplands College of Science and Technology Incorporated (UCSI), Kuala Lumpur 56000, Malaysia.
Arch Environ Contam Toxicol
November 2024
Jan Japenga Laboratory of Micropollutants (LMJJ), Biophysics Institute (IBCCF), Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brazil.
In general, mercury (Hg) undergoes biomagnification in aquatic systems. The absence of Hg biomagnification in a certain aquatic environment constitutes an exceptional finding and this seems to be the case for Sepetiba Bay, in Rio de Janeiro state (RJ), Brazil. There are three distinct ecological populations of Guiana dolphins in the Sepetiba Bay (SB)-Ilha Grande Bay (IGB) Complex, inhabiting: (1) the inner part of SB; (2) SB entrance; and (3) IGB.
View Article and Find Full Text PDFVestn Otorinolaringol
November 2024
Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!