A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design of hyaluronan-based dopant for conductive and resorbable PEDOT ink. | LitMetric

Conformable biocompatible conductive materials are increasingly sought for the development of bioelectronics. If additionally resorbable, they could serve for the design of transient implantable electronic devices, opening the way to new healthcare applications. Hyaluronan (HA) derivatives including sulfate and aminophenylboronic acid (PBA) groups (HAS-PBA) were therefore designed to serve as dopants of poly(3,4-ethylenedioxy)thiophene (PEDOT). The optimized HA sulfation protocol allowed good control on polymer sulfation degree while minimizing polymer chain degradation. Sulfated HA was shown to be degradable in physiological conditions. A synergy was observed between the sulfate negative charges and the PBA aromatic groups promoting hydrophobic interactions and π-stacking between PEDOT and HAS-PBA, to boost the material conductivity that reached 1.6 ± 0.2 S/cm in physiological conditions. Moreover the PEDOT:HAS-PBA material was not cytotoxic and could be formulated for easy processing by inkjet printing, appearing as promising candidate for the design of soft transient electronics for in vivo applications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.carbpol.2022.120345DOI Listing

Publication Analysis

Top Keywords

physiological conditions
8
design hyaluronan-based
4
hyaluronan-based dopant
4
dopant conductive
4
conductive resorbable
4
resorbable pedot
4
pedot ink
4
ink conformable
4
conformable biocompatible
4
biocompatible conductive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!