Background: The arteriovenous fistula (AVF) is prone to thrombosis which can be avoided by use of monitoring and surveillance programmes. Although surveillance imaging techniques have been shown to be more sensitive and specific than clinical monitoring during dialysis, monitoring may have significant advantages in terms of cost and time saving. In this study we evaluate the yield of two monitoring techniques [blood temperature monitoring (BTM) access recirculation (AR) and Kt/V via online-clearance-monitoring (OCM)].
Methods: In this single-centre prospective observational study, 101 patients were followed-up for one year. The primary outcome measure was a composite of AVF failure. OCM-Kt/V and BTM-AR were recorded at every dialysis session.
Results: Of all baseline characteristics only a prior history of percutaneous transluminal angioplasty (PTA) to the AVF conferred a significant change in AVF survival (failure events/100 pt years with prior PTA vs. without = 64.0 vs. 17.3, log-rank p = 0.0014; unadjusted hazard ratio (HR) 3.74 (95% CI 1.56-8.94) p = 0.003). Participants with baseline AR < 10% vs. > 15% had poorer AVF survival (p = 0.0002) and HR for baseline AR 10-15% group vs. AR > 15% group = 4.5 (95% CI 1.55-13.05). There was no combination of change in (Δ) AR, ΔKt/V or its presence over any number of dialysis sessions that provided an acceptable combination of sensitivity and specificity or discrimination for AVF failure.
Conclusions: BTM-AR and OCM-Kt/V are specific but insufficiently sensitive tools for the prediction of AVF failure. BTM-AR and OCM-Kt/V use at every dialysis session appears to add little to the traditional, infrequent use of these evaluations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s40620-022-01525-4 | DOI Listing |
Anal Chem
January 2025
Institute for Bioengineering of Catalonia (IBEC), Barcelona Institute of Science and Technology (BIST), 08028 Barcelona, Spain.
Nuclear magnetic resonance (NMR) spectroscopy is a valuable diagnostic tool limited by low sensitivity due to low nuclear spin polarization. Hyperpolarization techniques, such as dissolution dynamic nuclear polarization, significantly enhance sensitivity, enabling real-time tracking of cellular metabolism. However, traditional high-field NMR systems and bioreactor platforms pose challenges, including the need for specialized equipment and fixed sample volumes.
View Article and Find Full Text PDFHardwareX
December 2024
Brown University, School of Engineering, 184 Hope St, Providence, RI 02912, United States of America.
Open-channel flumes are an important tool in fluid mechanics research and education. However, the few commercially available small-scale flumes are generally expensive and lack complete characterization. In this work, we present an open-source, low-cost, modular benchtop laboratory flume that is designed to be accessible and reproducible.
View Article and Find Full Text PDFJ Fish Dis
December 2024
Institute for Marine and Antarctic Studies, University of Tasmania, Hobart, Tasmania, Australia.
Recirculating Aquaculture Systems (RAS) have been proposed as the future of aquaculture, because they can be used anywhere regardless of access to water, they offer high level of control over farming environment, including biosecurity, and are considered to be sustainable. However, despite of continuous development, there can be still issues with water quality affecting gill health of fish farmed in these systems. This review provides an overview of fish gill structure and gill immune response, and discusses the known impacts of RAS on gill health.
View Article and Find Full Text PDFAnn Biomed Eng
November 2024
Department of Biomedical Engineering, Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy.
Purpose: Arteriovenous fistula (AVF), the preferred vascular access for hemodialysis, is associated with high failure rate. The aim of this study was to investigate the potential of AVF sound auscultation in providing quantitative information on AVF hemodynamic conditions.
Methods: This single-center prospective study involved six patients with native radio-cephalic AVFs who underwent multiple follow-up visits.
J Vasc Access
October 2024
AUSL Pescara, Interventional Nephrology Unit, Via Fonte Romana, Pescara, Italy.
Background: The development of a high flow rate arteriovenous fistula (AVF) can expose the patient to development of heart failure due to increased cardiac preload and pulmonary hypertension.
Objectives: AVF flow measurement (Qa) is considered a screening tool for AVF surveillance, aiming to evaluate the access dysfunction and prevent complications, like a non-maturation, suspected stenosis, high-flow AVF, and distal ischemia. In the upper arm AVF, a high Qa may develops, which can expose the patient to the risk of high-output heart failure and ischemia.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!