A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Malpositioned Implant in the Esthetic Area: The Peri-Implant Plastic Surgery and Angulated Welded Abutment Approach. | LitMetric

Purpose: To describe the treatment of malpositioned implants in the esthetic area using the angulated welded abutment (AWA) approach together with peri-implant soft tissue surgery.

Materials And Methods: A clinical case with extreme buccal angulation of two implants in the anterior maxilla was used to illustrate the AWA technique. After implant impression-taking, digital analysis was used to determine the ideal prosthetic angulation of the abutment and the ideal position of its screw hole in relation to the gingival margin of the adjacent teeth. The AWA was designed in two combinable components that were meant to be welded together. Before the welding process, an angulated screw was included in the abutment. Since the angulated screw was inside the abutment, the screwdriver hole could be designed as narrow as possible and put in an ideal position. After periodontal and peri-implant surgery were carried out, the AWA was applied to the implants.

Results: The AWA allowed correction of the prosthetic axis. Moreover, relocation of the screw hole allowed the gingival tissue to creep over the abutment. In this way, a new esthetic restoration can be placed after the mucogingival surgery.

Conclusion: The excessive misangulation of the implants was efficiently recovered. Further studies are needed to evaluate long-term clinical success, and standardization of this technique is required for routine clinical use. Int J Prosthodont 2023;36:228-232. doi: 10.11607/ijp.759.

Download full-text PDF

Source
http://dx.doi.org/10.11607/ijp.7591DOI Listing

Publication Analysis

Top Keywords

esthetic area
8
angulated welded
8
welded abutment
8
ideal position
8
screw hole
8
angulated screw
8
abutment
6
awa
5
malpositioned implant
4
implant esthetic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!