Syncope prognosis is related to both its etiology and comorbidities, with cardiac syncope (CS) having higher risks for mortality and cardiovascular events than syncope of non-cardiac causes. Although a novel insertable cardiac monitor (ICM) is an effective diagnostic tool for unexplained syncope, decision regarding ICM implantation with a high pre-test likelihood of CS should contribute to economic cost reduction and avoidance of unnecessary complications. This study aimed to investigate clinical factors associated with CS after ICM implantation in patients with unexplained syncope. This retrospective observational study included 31 consecutive patients with ICM implantation for syncope between September 2016 and August 2021. The initial examinations for syncope included a detailed history, physical examination, blood tests, 12-lead electrocardiograms, and transthoracic echocardiography. Of the 31 patients, 13 (41.9%) experienced recurrent CS during follow-up (676 ± 469 days). Among several clinical factors, syncope-related minor injuries (p = 0.017) and higher brain natriuretic peptide (BNP; p = 0.043) levels were significantly associated with CS. Moreover, multivariable analysis showed that both syncope-related minor injuries (odds ratio, 11.2; 95% confidence interval, 1.4-88.4; p = 0.022) and BNP higher than 64.0 pg/mL (odds ratio, 7.0; 95% confidence interval, 1.1-44.2; p = 0.038) were independent predictors of CS after ICM implantation. In conclusion, a history of minor injury secondary to syncope and higher BNP levels were independent CS predictors in patients receiving ICM for syncope. These results emphasized the utility of ICM implantation early in the diagnostic journey of patients presenting with CS predictors requiring specific treatments.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00380-022-02212-xDOI Listing

Publication Analysis

Top Keywords

icm implantation
20
unexplained syncope
12
syncope
11
cardiac syncope
8
patients unexplained
8
insertable cardiac
8
cardiac monitor
8
syncope higher
8
clinical factors
8
syncope-related minor
8

Similar Publications

Background: Implantable cardiac monitors (ICMs) provide valuable insights into managing atrial fibrillation (AF). Data suggest that ICMs increase AF detection, but their impact on management is still uncertain.

Objectives: To evaluate and compare the impact of ICMs on the clinical management of AF.

View Article and Find Full Text PDF

Background: Atrial fibrillation (AF) has a significant impact on health and quality of life. The relationship of AF burden and temporal patterns of AF on patient symptoms, outcomes, and healthcare utilization is unknown. Insertable cardiac monitors (ICMs) are a strategic and as yet untapped, tool to investigate these relationships.

View Article and Find Full Text PDF

Aim: To evaluate the predictive value of preoperative echocardiographic parameters for occurrence of VAs in patients with preexisting ICD undergoing LVAD implantation.

Methods And Results: All consecutive patients (n = 264) with previous ICD who underwent LVAD surgery between May 2011 and December 2019 at our institution were included. The patients were predominantly male (89%) with NICM (59%) and a mean age of 59 ± 10 years.

View Article and Find Full Text PDF

Aims: We aim to evaluate the incidence of atrial fibrillation (AF) in a large real-world cohort of patients implanted with an insertable cardiac monitor (ICM) who had a clinical history of symptomatic heart failure (HF) with reduced or preserved left ventricular ejection fraction (LVEF).

Methods: Patients with an ICM and a history of HF events were identified from the Optum® de-identified Electronic Health Record dataset merged with an ICM device dataset collected during 2007-2021. All ICM-detected AF episodes that were available with ≥30-s of ECG at onset were adjudicated using artificial intelligence (AI model).

View Article and Find Full Text PDF
Article Synopsis
  • * Bilateral CSD (BCSD) shows an approximate 60% reduction in implantable cardioverter defibrillator shocks and over 50% one-year survival without shock or transplant, while the 2017 guidelines endorse the left CSD for specific RVT types.
  • * Despite the promising results, many studies have small sample sizes leading to potential underreporting of complications; more research is needed to fully understand the long
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!