Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: The iodinated contrast material (ICM) shortage of 2022 has affected healthcare systems worldwide, forcing institutions to adapt by implementing interventions to conserve ICM without compromising patient care. We aim to present the practices proven to be effective in reducing ICM consumption to improve resource allocation in trauma patients.
Methods: A literature search of PubMed, Google Scholar, and Cochrane was conducted. Studies investigating the utility of ICM in the management of trauma & emergency surgery patients, as well as institutional interventions that were implicated as a response to the ICM shortage of 2022 were included for review.
Results: Eight articles were selected and reviewed. The use of alternative, non-contrast-enhanced imaging modalities, particularly non-contrast-enhanced CT (NECT), was found to be effective in reducing ICM consumption. Other institutions have implemented strategies to reduce the ICM dose for each imaging study performed, including decreasing ICM dose itself as well as reducing tube voltage, which was shown to reduce ICM use by 50%. Waste minimization by splitting single-dose contrast vials into smaller aliquots utilized for multiple imaging studies has also been an effective method. Additionally, assembling a Radiology Command Center Team, responsible for monitoring ICM supplies while offering 24/7 consults regarding options for alternative imaging, has resulted in an overall reduction in contrast consumption of 50% in 7 days.
Conclusion: In response to the ICM shortage of 2022, most healthcare institutions have found the use of alternative imaging modalities to be effective in reducing ICM consumption. Other effective measures include ICM dose reduction and ICM waste minimization.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ajem.2022.11.016 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!