A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluating an under-mattress sleep monitor compared to a peripheral arterial tonometry home sleep apnea test device in the diagnosis of obstructive sleep apnea. | LitMetric

AI Article Synopsis

  • The study aimed to compare the apnea-hypopnea index (AHI) from a home sleep apnea test (PAT-HSAT) and an under-mattress device (WSA) over multiple nights in patients suspected of having obstructive sleep apnea (OSA).
  • 35 out of 61 enrolled patients completed the study, with results showing that the WSA-AHI significantly differed from the PAT-AHI, both under different desaturation criteria.
  • Although the WSA provides undisruptive AHI estimates, its accuracy compared to PAT-AHI varies, suggesting that further research is needed to refine its clinical application.

Article Abstract

Study Objectives: To evaluate whether or not the apnea-hypopnea index (AHI) from a peripheral arterial tonometry (PAT) home sleep apnea test (HSAT) is equivalent to the AHI provided by the mean of one, three, or seven nights from the Withings Sleep Analyzer (WSA) under-mattress device.

Methods: We prospectively enrolled patients with suspected OSA in whom a PAT-HSAT was ordered. Eligible patients used the WSA for seven to nine nights. PAT data were scored using the device's intrinsic machine learning algorithms to arrive at the AHI using both 3% and 4% desaturation criteria for hypopnea estimations (PAT3%-AHI and PAT4%-AHI, respectively). These were then compared with the WSA-estimated AHI (WSA-AHI).

Results: Of 61 patients enrolled, 35 completed the study with valid PAT and WSA data. Of the 35 completers 16 (46%) had at least moderately severe OSA (PAT3%-AHI ≥ 15). The seven-night mean WSA-AHI was 2.13 (95%CI =  - 0.88, 5.14) less than the PAT3%-AHI, but 5.64 (95%CI = 2.54, 8.73) greater than the PAT4%-AHI. The accuracy and area under the receiver operating curve (AUC) using the PAT3%-AHI ≥ 15 were 77% and 0.87 and for PAT4%-AHI ≥ 15 were 77% and 0.85, respectively. The one-, three-, or seven-night WSA-AHI were not equivalent to either the 3% or 4% PAT-AHI (equivalency threshold of ± 2.5 using the two one-sided t-test method).

Conclusions: The WSA derives estimates of the AHI unobtrusively over many nights, which may prove to be a valuable clinical tool. However, the WSA-AHI over- or underestimates the PAT-AHI in clinical use, and the appropriate use of the WSA in clinical practice will require further evaluation.

Trial Registration: ClinicalTrials.gov Identifier: NCT04778748.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11325-022-02751-7DOI Listing

Publication Analysis

Top Keywords

sleep apnea
12
peripheral arterial
8
arterial tonometry
8
apnea test
8
seven-night wsa-ahi
8
≥ 77%
8
sleep
5
ahi
5
wsa
5
evaluating under-mattress
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!