A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Radiation Dose Exposure to Patients During Transcatheter Patent Ductus Arteriosus Closure via the Arterial Route. | LitMetric

Objective This study aims to evaluate the radiation dose for transcatheter patent ductus arteriosus (PDA) via the arterial route and compare it with previously published benchmarks. Background Exposure to radiation in the catheterization lab can cause skin injury and cancer in the long run, especially in pediatric patients with complex heart conditions, which necessitate serial catheterizations. Therefore, measuring the patient radiation dose and establishing a benchmark for each cardiac interventional procedure is essential. Material and methods In this prospective study, 34 patients with transcatheter patent ductus arteriosus closure via an arterial route were included. Patients who had silent PDAs, no left heart dilatation and PDA size of less than 2mm had PDA closed via an arterial route. All the study group patients received an Amplatzer duct occluder II-additional size device (St. Jude Medical Corp, St. Paul, MN) using biplane flat-panel fluoroscopy equipment adjusted in accordance with the pediatric parameters. Patients' dose area product, air kerma and fluoroscopy time were recorded in the catheterization lab and finally compared with internationally published reference data. Results Of 73 patients who had transcatheter patent ductus arteriosus closure between April 2021 to December 2021, 34 patients who had a PDA closure via an arterial route were enrolled. The median age and weight were 11.5 (4-168) months and 10.5 (6-31) kg. Twenty-one (61.8%) were males, and 13 (38.2%) were males. The median radiation dose parameters were as follows: air kerma 11 (3-42) milliGray, dose area product 131 (33-443) microGray per m, median dose area product indexed to weight 12 (1-48) microGray m per kg, fluoroscopy time 2 (2-4) min and frame rate 15 (7.5-15) frames per second. Due to many factors, our radiation dose parameters were less than internationally published reference values for transcatheter PDA closure. Conclusion Patient selection, detailed pre-catheterization echocardiography and procedure planning are essential for accomplishing device closure of PDA with a significant reduction in radiation dose. Hemodynamic assessment in the catheterization lab is unnecessary for most PDA patients. Additionally, a next-generation imaging platform equipped with flat-panel detectors and adjusted for pediatric settings and a fluoro recording option can be used to reduce radiation exposure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9691471PMC
http://dx.doi.org/10.7759/cureus.30685DOI Listing

Publication Analysis

Top Keywords

radiation dose
24
arterial route
20
transcatheter patent
16
patent ductus
16
ductus arteriosus
16
patients transcatheter
12
arteriosus closure
12
closure arterial
12
catheterization lab
12
dose area
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!