Minimally-invasive thermal ablation procedures have become clinically accepted treatment options for tumors and metastases. Continuous and reliable monitoring of volumetric heat distribution promises to be an important condition for successful outcomes. In this work, an adaptive bioheat transfer simulation of 3D thermometry maps is presented. Pennes' equation model is updated according to temperature maps generated by uniformly distributed 2D MR phase images rotated around the main axis of the applicator. The volumetric heat diffusion and the resulting shape of the ablation zone can be modelled accurately without introducing a specific heat source term. Filtering the temperature maps by extracting isotherms reduces artefacts and noise, compresses information of the measured data and adds physical a priori knowledge. The inverse heat transfer for estimating values of the simulated tissue and heating parameters is done by reducing the sum squared error between these isotherms and the 3D simulation. The approach is evaluated on data sets consisting of 13 ex vivo bio protein phantoms, including six perfusion phantoms with simulated heat sink effects. Results show an overall average Dice score of 0.89 ± 0.04 (SEM < 0.01). The optimization of the parameters takes 1.05 ± 0.26 s for each acquired image. Future steps should consider the local optimization of the simulation parameters instead of a global one to better detect heat sinks without a priori knowledge. In addition, the use of a proper Kalman filter might increase robustness and accuracy if combined with our method.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9701800PMC
http://dx.doi.org/10.1038/s41598-022-24911-1DOI Listing

Publication Analysis

Top Keywords

simulation thermometry
8
thermometry maps
8
volumetric heat
8
temperature maps
8
priori knowledge
8
heat
6
adaptive simulation
4
maps
4
maps interventional
4
interventional mr-guided
4

Similar Publications

: Accurate reconstruction of internal temperature fields from surface temperature data is critical for applications such as non-invasive thermal imaging, particularly in scenarios involving small temperature gradients, like those in the human body. : In this study, we employed 3D convolutional neural networks (CNNs) to predict internal temperature fields. The network's performance was evaluated under both ideal and non-ideal conditions, incorporating noise and background temperature variations.

View Article and Find Full Text PDF

Background: The anterolateral thigh (ALT) flap is a reliable and versatile flap with the ideal characteristics for soft-tissue reconstruction. However, as it is known for its highly variable anatomy, it requires preoperative perforator localization to optimize flap design and dissection of the flap. Dynamic Infrared Thermography (DIRT) is a non-invasive and quick imaging method that provides real-time information.

View Article and Find Full Text PDF

Thermal Characterization of Ferroelectric AlBN for Nonvolatile Memory.

ACS Appl Mater Interfaces

December 2024

Department of Materials Science and Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States.

Boron (B)-substituted wurtzite AlN (AlBN) is a recently discovered wurtzite ferroelectric material that offers several advantages over ferroelectric HfZrO and PbZrTiO. Such benefits include a relatively low growth temperature as well as a thermally stable, and thickness-stable ferroelectric polarization; these factors are promising for the development of ferroelectric nonvolatile random-access memory (FeRAM) that are CMOS-compatible, scalable, and reliable for storing data in harsh environments. However, wurtzite ferroelectric materials may undergo exacerbated self-heating upon polarization switching relative to other ferroelectric materials; the larger energy loss is anticipated due to the higher coercive field and remanent polarization.

View Article and Find Full Text PDF

The constant spectral emissivity decoupling method within current wide-spectrum thermometry theories stands as a primary factor contributing to accuracy degradation. This creates a deadlock in the current radiation thermometry framework, where the system's two-dimensional analytical capabilities and resolution accuracy cannot be concurrently achieved, becoming a major theoretical obstacle in the development of this technique. Consequently, based on the Taylor series de-integration method under the wide spectral framework, and taking the first and second derivative terms of spectral emissivity as the starting point, a wide spectral optimization temperature solution theory based on three-directional difference method is proposed.

View Article and Find Full Text PDF

Effective Rapid Fluorescence Lifetime Imaging of the Brain: A Novel Approach Using Upconversion Photoluminescence Lifetime Based on Gate-Width Acquisition.

Nano Lett

November 2024

Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.

Article Synopsis
  • The study presents a new data acquisition method that uses three adjustable gates to improve the resolution of rapid lifetime imaging in upconversion photoluminescence, addressing limitations of existing techniques.
  • This method allows for the visualization of capillary networks and pH mapping in mouse brain vasculature by utilizing enhanced brightness from specific nanoparticles.
  • Results show a high accuracy in fluorescence duration measurements, making it a fast and effective solution for multiplex brain imaging compared to traditional methods.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!