Simultaneous determination of NTB-3119, a novel anti-tuberculosis agent, and its major metabolites in mouse plasma by LC-MS/MS and its application in preclinical pharmacokinetics study.

J Pharm Biomed Anal

Department of Drug Metabolism, State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Beijing Laboratory of Non-Clinical Drug Metabolism and PK/PD Study, Beijing Key Laboratory of Active Substance Discovery and Druggability Evaluation, Institute of Materia Medica, Peking Union Medical College and Chinese Academy of Medical Sciences, 1 Xian Nong Tan Street, Beijing 100050, PR China; Chinese Academy of Medical Sciences Key Laboratory of Anti-DR TB Innovative Drug Research, Institute of Materia Medica, Peking Union Medical College and Chinese Academy of Medical Sciences, 1 Xian Nong Tan Street, Beijing 100050, PR China.

Published: February 2023

NTB-3119, a novel benzothiopyranone derivative, has been developed as a potential anti-tuberculosis(TB) drug with strong activity. In this study, three major metabolites of NTB-3119 were firstly identified in vitro and in vivo. A sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was established for the quantitative analysis of NTB-3119 and its major metabolites NTB-3190, NTB-3202 and NTB-3204 in mouse plasma. The plasma samples were processed by protein precipitation with organic solvent. NTB-3119, NTB-3190, NTB-3202, NTB-3204 and NTB-4A (Internal Standard, IS) were separated by a Zorbax-SB C column (100 mm × 2.1 mm, 3.5 µm) with a gradient mobile phase of acetonitrile/water at a flow rate of 0.25 mL/min. The analytes were detected by electrospray positive ion mode in Parallel Reaction Monitoring (PRM) mode on a high resolution mass spectrum (HRMS, Thermo Q Executive). The monitored transitions were m/z 456.15632 → 360.06137 for NTB-3119, m/z 426.18214 → 246.01891 for NTB-3190, m/z 472.15124 → 360.06143 for NTB-3202, m/z 442.17706 → 246.01903 for NTB-3204 and m/z 337.13691 → 163.02081 for NTB-4A, respectively. Good linearity was conducted in the range of 5-2000 ng/mL for NTB-3119, NTB-3202 and NTB-3204 as well as 2.5-1000 ng/mL for NTB-3190. The inter- and intra-batch precision (RSD%) were both lower than 13.3 %, with the accuracy ranged from 88.0 % to 108.1 %. The analytes were proved to be stable during all samples storage, preparation and analytic procedures. The validated method was successfully applied to study the pharmacokinetics and bioavailability of NTB-3119 after oral treatment in Balb/c mouse.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2022.115172DOI Listing

Publication Analysis

Top Keywords

major metabolites
12
ntb-3202 ntb-3204
12
ntb-3119
8
ntb-3119 novel
8
mouse plasma
8
ntb-3190 ntb-3202
8
m/z
5
5
simultaneous determination
4
determination ntb-3119
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!